background image

4

Basic Operation 

continued

LINE POWER LED: 

This  green  light  will  illuminate  whenever  the  UPS  is  ON  and 

receiving normal AC line power.

BATTERY POWER LED: 

This  yellow  light  will  illuminate  when  the  UPS  is  providing 

equipment with battery power.

REPLACE BATTERY LED: 

This red light will illuminate continuously after the UPS runs 

a self-test to indicate that the battery is weak. If it remains lit after allowing the UPS to 
charge for twelve hours and running a second self-test, contact Tripp Lite for service.

OVERLOAD LED: 

This red light will illuminate continuously to indicate that the UPS is 

overloaded when the UPS is providing power from battery or after the UPS runs a self-
test. If it lights up, immediately remove some of the equipment connected to the “UPS/
Surge” outlets and run a self-test. Large overloads may cause the UPS to shut down.

Battery Backup Protected/Surge Protected Outlets: 

Provide both battery backup 

and surge protection. Plug your computer, monitor and other critical equipment into 

these outlets. 

NOTE

: DO NOT PLUG LASER PRINTERS INTO THESE OUTLETS.

Surge-Only Protected Outlets: 

Provide surge and line noise protection, not battery 

backup. Plug equipment (such as a printer, scanner or fax machine) that does not 

require battery backup during a utility power failure into these outlets.

USB Communication Port: 

This  port  can  connect  your  UPS  to  any  computer  for 

automatic file saves and unattended shutdown in the event of a power failure. Use 

with Tripp Lite’s PowerAlert Software and appropriate USB cable. A USB cable may be 

included with your UPS. You can obtain the PowerAlert software FREE via the Web at 

www.tripplite.com. Any user-supplied USB cable may then be used to connect your 

UPS to your computer. 

NOTE

: This connection is optional. The UPS will work properly 

without this connection.

Tel/DSL Protection Jacks: 

Stop surges on the phone or fax line. A built-in splitter 

(one jack in and two jacks out) allows you to simultaneously protect and connect two 
devices sharing a single line. Connecting your equipment to these jacks is optional. 
Your UPS will work properly without this connection.

Battery Replacement Door (bottom panel, not shown): 

Under normal conditions, 

the original battery in your UPS will last several years. Battery replacement should 
be  performed  only  by  qualified  service  personnel.  Refer  to  “Battery  Warnings”  in 
the  Safety  Section.  Should  your  UPS  require  battery  replacement,  visit  Tripp  Lite 
on  the  web  at  www.tripplite.com/support/battery/index.cfm  to  locate  the  specific 
replacement battery for your UPS.

201203081 933176.indb   4

3/20/2012   4:01:33 PM

Summary of Contents for AVR750U

Page 1: ...All rights reserved Not suitable for mobile applications 1111 W 35th Street Chicago IL 60609 USA www tripplite com support AVR750U W a r r a n t y R e g i s t r a t i o n r e g i s t e r o n l i n e t o d a y f o r a c h a n c e t o w i n a F R E E T r i p p L i t e p r o d u c t w w w t r i p p l i t e c o m w a r r a n t y 201203081 933176 indb 1 3 20 2012 4 01 33 PM ...

Page 2: ...PS and may affect the surge suppressor and UPS warranties Battery Warnings Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceable parts inside Batteries can present a risk of electrical shock and burn from high short circuit current Observe proper precautions Do not dispose of the batteries in a fire Do not open the UPS or batteries Do not s...

Page 3: ...tton to start the UPS A beep should sound when the UPS starts 3 If the UPS still does not start contact Tripp Lite Tech Support for assistance ON OFF MUTE TEST Button To Turn the UPS ON Press and hold the ON OFF MUTE TEST button until you hear the system beep and then release the button The system is now turned ON If utility power is absent pressing the Button will cold start the UPS i e turn it o...

Page 4: ...canner or fax machine that does not require battery backup during a utility power failure into these outlets USB Communication Port This port can connect your UPS to any computer for automatic file saves and unattended shutdown in the event of a power failure Use with Tripp Lite s PowerAlert Software and appropriate USB cable A USB cable may be included with your UPS You can obtain the PowerAlert ...

Page 5: ...If the problem requires service visit www tripplite com support and click the Product Returns link From here you can request a Returned Material Authorization RMA number which is required for service This simple on line form will ask for your unit s model and serial numbers along with other general purchaser information The RMA number along with shipping instructions will be emailed to you Any dam...

Page 6: ... subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection...

Page 7: ...ión rápida 9 Operación básica 9 Almacenamiento y Servicio 11 English 1 2012 Tripp Lite Todos los derechos reservados AVR750U No conveniente para los usos móviles 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 201203081 933176 indb 7 3 20 2012 4 01 33 PM ...

Page 8: ...ñar el UPS y afectar las garantías del supresor de sobretensiones y del UPS Advertencias sobre la batería Su UPS no requiere un mantenimiento de rutina No abra su UPS por ninguna razón No hay partes que requieran mantenimiento por parte del usuario en su interior Debido a que las baterías presentan un peligro de choque eléctrico y quemaduras por las altas corrientes de cortocircuito tome las preca...

Page 9: ...lsarlo un botón de ON OFF MUTE TEST ENCENDIDO APAGADO SILENCIO PRUEBA durante al menos un segundo para iniciar el UPS Sonará un pitido cuando se encienda el UPS 3 Si el UPS aún no se inicia comuníquese con el Soporte Técnico de Tripp Lite para obtener asistencia Para ENCENDER el UPS Presione y mantenga el botón ON OFF MUTE TEST ENCENDIDO APAGADO SILENCIO PRUEBA hasta que escuche que el sistema emi...

Page 10: ...ionan respaldo de baterías y protección contra sobretensiones Conecte su computadora su monitor y otros equipos críticos en estas salidas NOTA NO CONECTE IMPRESORAS LÁSER EN ESTAS SALIDAS Salidas protegidas contra sobretensiones Proporcionan protección contra sobretensiones y ruido en la línea pero no respaldo de batería Conecte equipos como impresora escáner o fax que no requieran respaldo de bat...

Page 11: ...nico visite www tripplite com support Antes de devolver su producto para servicio técnico siga estos pasos 1 Revise la instalación y los procedimientos de operación que se encuentran en este manual para asegurarse de que el problema de servicio no se debe a una mala lectura de las instrucciones 2 Si el problema persiste no se comunique ni devuelva el producto al mayorista En cambio visite www trip...

Page 12: ...12 1111 W 35th Street Chicago IL 60609 USA www tripplite com support 2012 Tripp Lite Todos los derechos reservados 201203081 933176 ES 201203081 933176 indb 12 3 20 2012 4 01 34 PM ...

Reviews: