19/65
4.2.3. SENSOR
4.2.3.1.
ALARM DURATION
It indicates how long the alarm lasts after it sets [OFF, 05, 10, 15, 20, 25, 30, CONT]. It sets the
alarm duration (in seconds) after alarm is activated. Select “DISABLE” to deactivate sensor re-
cording or if there is no sensor installed in DVR system. To continue the alarm signal on, to select
as CONT
4.2.3.2.
SENSOR - 1, 2, 3, 4
Each channel has to be set by the type of SENSOR. The initial value is [DISABLE], you can select
[NORMAL OPEN TYPE/ NORMAL CLOSE TYPE].
4.2.4. MOTION DETECTION
Select Motion detection. It is available when the system recognizes the movement.