background image

16

LIMITED WARRANTY

Triplett warrants instruments and test equipment manufactured by it to 
be free from defective material or workmanship and agrees to repair or 
replace such products which, under normal use and service, disclose 
the defect to be the fault of our manufacturing, with no charge within 
two  years  (PairMaster)  –  one  year  (Remotes)  of  the  date  of  original 
purchase for parts and labor. If we are unable to repair or replace the 
product, we will make a refund of the purchase price. Consult the In-
struction Manual for instructions regarding the proper use and servicing 
of instruments and test equipment. Our obligation under this warranty 
is limited to repairing, replacing, or making refund on any instrument or 
test equipment which proves to be defective within two years (PairMas-
ter) - one year (Remotes) from the date of original purchase.

 
This warranty does not apply to any of our products which have been 
repaired or altered by unauthorized persons in any way so as, in our 
sole judgment, to injure their stability or reliability, or which have been 
subject to misuse, abuse, misapplication, negligence, accident or which 
have had the serial numbers altered, defaced, or removed. Accessories, 
including batteries and fuses not of our manufacture used with this prod-
uct are not covered by this warranty. 

To register a claim under the provisions of this warranty, contact Trip-
lett’s CustomerService Department for a Return Authorization Number 
(RMA)  and  return  instructions.  No  returned  product  will  be  accepted 
without  an  RMA  number.  Upon  our  inspection  of  the  product,  we  will 
advise you as to the disposition of your claim. 

ALL  WARRANTIES  IMPLIED  BY  LAW ARE  HEREBY  LIMITED TO A 
PERIOD OF TWO YEARS (PAIRMASTER) – ONE YEAR (REMOTES) 
AND THE  PROVISIONS  OF THE  WARRANTY ARE  EXPRESSLY  IN 
LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED. 

The purchaser agrees to assume all liability for any damages and bodily 
injury which may result from the use or misuse of the product by the 
purchaser, his employees, or others, and the remedies provided for in 
this warranty are expressly in lieu of any other liability Triplett may have, 
including incidental or consequential damages.

 
Some states (USA ONLY) do not allow the exclusion or limitation of in-
cidental or consequential damages, so the above limitation or exclusion 
may not apply to you. No representative of Triplett or any other person 
is authorized to extend the liability of Triplett in connection with the sale 
of its products beyond the terms hereof. 

Triplett reserves the right to discontinue models at any time, or change 
specifications, price or design, without notice and without incurring any 
obligation. This warranty gives you specific legal rights, and you may 
have other rights which vary from state to state.

Summary of Contents for PairMaster 3240-22

Page 1: ...PairMaster Lan Cable Test Set Instruction Manual TRIPLETT...

Page 2: ......

Page 3: ...result in a risk of fire electric shock or injury Do not attempt to service this unit There are no user serviceable parts inside this unit WARNING This test set has been designed with your safety in...

Page 4: ...BLE OF CONTENTS SECTION 1 OVERVIEW 3 FEATURES 5 SECTION 2 OPERATING INSTRUCTIONS 8 FAULT CODES 10 DISPLAY FACES 11 SECTION 3 SPECIAL CABLE TESTING 13 SECTION 4 SPECIFICATIONS 14 ACCESSORIES 15 WARRANT...

Page 5: ...of the cable s conductors identifying any Opens Shorts or Miswiring The results are displayed by simple PASS FAIL indicators If a fault is detected a digital display shows an error code that identifie...

Page 6: ...4 Cable Identification User Diagram Figure 1 To Remote Locations...

Page 7: ...CATOR LED to light up The LED will remain ON until the overvoltage condition is corrected or the Remote Identifier is removed from the cable 2 REMOTE IDENTIFIER The Remote Identifier is a small module...

Page 8: ...nder PASS conditions the display shows the number of the Remote Identifier attached to the cable Under FAIL conditions the appropriate Fault Code is displayed see page 11 5 PASS FAIL LEDs Each pair in...

Page 9: ...7...

Page 10: ...uplers is recommended to reduce wear on the PairMaster s RJ 45 jack Press the PUSH TO TEST PTT button to begin testing the cable for proper wiring Observe the digital display Upon press ing the PTT bu...

Page 11: ...ower up i e the PairMaster tests each pair of the cable sequentially The pairs consist of the following conductors 1 2 3 6 4 5 7 8 The PASS FAIL results of each pair are displayed immediately fol lowi...

Page 12: ...or both conductors of a pair do not have continuity SHORTED PAIR The conductors of a pair are shorted together CROSSED PAIR One or both conductors of a pair are shorted to conductors of another pair S...

Page 13: ...11 Figure 2...

Page 14: ...inform the user of the highest priority fault The user upon checking the pair will discover the lower priority fault also In most applications the cable is wired incorrectly and will require rewiring...

Page 15: ...ver many LAN installations such as Ethernet or Token Ring require an 8 pin RJ 45 connection but only use two of the four pairs see fig 6 These two types of configurations are no problem for the PairMa...

Page 16: ...Ethernet and Token Ring CABLE PAIRS TESTED 1 2 3 6 4 5 7 8 CONNECTOR RJ 45 FAULTS DETECTED Open pairs Shorted pairs Crossed pairs Spilt Pairs Transposed Pairs Reversed pairs and Double Spilt pairs NE...

Page 17: ...rroneous readings POWER SUPPLY PairMaster 9 Volt Alkailne Battery Remote Identifier Passive no battery required ENVIRONMENT Storage 20 C to 60 C Operating 0 C to 50 C SIZE LxWxH PairMaster 6 0 x 3 3 x...

Page 18: ...covered by this warranty To register a claim under the provisions of this warranty contact Trip lett s CustomerService Department for a Return Authorization Number RMA and return instructions No retu...

Page 19: ......

Page 20: ...TRIPLETT Test Equipment Tools www triplett com 850 Perimeter Road Manchester NH 03103 PHONE 800 TRIPLETT FAX 603 622 2960...

Reviews: