10
11
POWER-UP:
Displayed immediately after push-to- test (PTT)
button is pressed, if everything is normal.
LOW BATTERY:
Displayed immediately after push-to-test button
is pressed if battery voltage is low (less than 6.5 volts).
FAULT CODES
OVERVOLTAGE:
Damaging voltage is present on the cable. The
unit will flash “OL “ until the damaging voltage is removed or
the PairMaster turns off.
OPEN PAIR:
One or both conductors of a pair do not have
continuity.
SHORTED PAIR:
The conductors of a pair are shorted together.
CROSSED PAIR:
One or both conductors of a pair are shorted
to conductors of another pair.
SPLIT PAIR:
Two conductors in the cable are switched, “split-
ting” two pairs.
TRANSPOSED PAIR:
Two pairs in the cable are switched.
REVERSED PAIR:
The conductors of an individual pair are
reversed in polarity at one end of the cable.
DOUBLE SPLIT PAIR:
The NEXT test fails. The conductors of
two pairs have correct continuity but excessive crosstalk.
NO ID:
(Flashes) The cable can not be identified.