background image

PairMaster

Lan Cable

Test Set

Instruction Manual

TRIPLETT

Summary of Contents for PairMaster 3240-22

Page 1: ...PairMaster Lan Cable Test Set Instruction Manual TRIPLETT...

Page 2: ......

Page 3: ...result in a risk of fire electric shock or injury Do not attempt to service this unit There are no user serviceable parts inside this unit WARNING This test set has been designed with your safety in...

Page 4: ...BLE OF CONTENTS SECTION 1 OVERVIEW 3 FEATURES 5 SECTION 2 OPERATING INSTRUCTIONS 8 FAULT CODES 10 DISPLAY FACES 11 SECTION 3 SPECIAL CABLE TESTING 13 SECTION 4 SPECIFICATIONS 14 ACCESSORIES 15 WARRANT...

Page 5: ...of the cable s conductors identifying any Opens Shorts or Miswiring The results are displayed by simple PASS FAIL indicators If a fault is detected a digital display shows an error code that identifie...

Page 6: ...4 Cable Identification User Diagram Figure 1 To Remote Locations...

Page 7: ...CATOR LED to light up The LED will remain ON until the overvoltage condition is corrected or the Remote Identifier is removed from the cable 2 REMOTE IDENTIFIER The Remote Identifier is a small module...

Page 8: ...nder PASS conditions the display shows the number of the Remote Identifier attached to the cable Under FAIL conditions the appropriate Fault Code is displayed see page 11 5 PASS FAIL LEDs Each pair in...

Page 9: ...7...

Page 10: ...uplers is recommended to reduce wear on the PairMaster s RJ 45 jack Press the PUSH TO TEST PTT button to begin testing the cable for proper wiring Observe the digital display Upon press ing the PTT bu...

Page 11: ...ower up i e the PairMaster tests each pair of the cable sequentially The pairs consist of the following conductors 1 2 3 6 4 5 7 8 The PASS FAIL results of each pair are displayed immediately fol lowi...

Page 12: ...or both conductors of a pair do not have continuity SHORTED PAIR The conductors of a pair are shorted together CROSSED PAIR One or both conductors of a pair are shorted to conductors of another pair S...

Page 13: ...11 Figure 2...

Page 14: ...inform the user of the highest priority fault The user upon checking the pair will discover the lower priority fault also In most applications the cable is wired incorrectly and will require rewiring...

Page 15: ...ver many LAN installations such as Ethernet or Token Ring require an 8 pin RJ 45 connection but only use two of the four pairs see fig 6 These two types of configurations are no problem for the PairMa...

Page 16: ...Ethernet and Token Ring CABLE PAIRS TESTED 1 2 3 6 4 5 7 8 CONNECTOR RJ 45 FAULTS DETECTED Open pairs Shorted pairs Crossed pairs Spilt Pairs Transposed Pairs Reversed pairs and Double Spilt pairs NE...

Page 17: ...rroneous readings POWER SUPPLY PairMaster 9 Volt Alkailne Battery Remote Identifier Passive no battery required ENVIRONMENT Storage 20 C to 60 C Operating 0 C to 50 C SIZE LxWxH PairMaster 6 0 x 3 3 x...

Page 18: ...covered by this warranty To register a claim under the provisions of this warranty contact Trip lett s CustomerService Department for a Return Authorization Number RMA and return instructions No retu...

Page 19: ......

Page 20: ...TRIPLETT Test Equipment Tools www triplett com 850 Perimeter Road Manchester NH 03103 PHONE 800 TRIPLETT FAX 603 622 2960...

Reviews: