background image

 
 

Display Description 

 

 

1.  Moisture Drop icons (one for low moisture, two for medium, and three 
for high) 

 

2.  Wood mode 

  

3.  Building Material mode 

  

4.  Beeper active icon 

 

  

5.  Moisture reading 

  

6.  Digital reading in % (relative) 
7. Display Lock Mode 
8. Battery Status 

 

 
 
 

 

Operation 

  

Powering the Meter and Self-Calibration 

 

Long press the power

 

 

button to switch the meter on/off. The meter 

beeps and displays

 ON 

as it powers up. If the meter does not switch on, 

please check the battery. The meter emits audible tones and performs a 
self-calibration upon start-up. Keep the measurement sensor at least 8 to 
10 cm (3 to 4”) from hands and objects during calibration. The calibration 
reading must not exceed 0.5. If so, re-calibrate ensuring that hands or 
other objects are clear of the sensor. Note: Calibrate the meter whenever 
moving from one measurement area to another.

 

 

Auto Power OFF 

 

The meter will automatically power OFF if the reading stays 0% for 3 
minutes. If the meter detects readings, other than 0%, it will not 
automatically power OFF. 

 

Display Hold Lock 

 

Short press the Display Lock button

 

 

to freeze the displayed 

reading.

 The 

 

icon is visible on the display when Display Lock is 

active. Press 

 again to return to the normal operating mode. 

 

 

Summary of Contents for MS120

Page 1: ...ding materials such as wallboard sheet rock cardboard plaster concrete and mortar The MS120 also offers auto power off APO display lock hold and self calibration features The MS120 is ideal for building restoration projects and applications where moisture detection on floors and under carpets is critical The MS120 is also a handy tool for analyzing the effects of water leakage behind walls and in ...

Page 2: ...ess than the maximum depth of penetration may result in unreliable moisture readings in these cases you can stack material on top of the measured surface to increase the thickness The MS120 also produces audible tones and moisture droplet display icons to indicate moisture level The audible tone rate and number of droplets increase as the moisture level increases The MS120 also produces audible to...

Page 3: ...elf calibration upon start up Keep the measurement sensor at least 8 to 10 cm 3 to 4 from hands and objects during calibration The calibration reading must not exceed 0 5 If so re calibrate ensuring that hands or other objects are clear of the sensor Note Calibrate the meter whenever moving from one measurement area to another Auto Power OFF The meter will automatically power OFF if the reading st...

Page 4: ...uld be larger than the sensor surface area 3 Observe the displayed relative readings view the displayed moisture droplet icon s more drops indicate higher moisture levels and listen for the audible beeping faster beeping indicates higher moisture there are eight intensity levels As discussed in the Measurement Considerations section the displayed reading is an average of the moisture measured over...

Page 5: ...ke used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment Care and Cleaning Store the meter in an environmentally stable dus...

Page 6: ...rating Conditions 5 45oC 41 113oF 80 RH max Storage Conditions 0 50oC 32 122oF 85 RH max Dimensions 170 x 65 x 30mm 6 7 x 2 6 x 1 2 Weight 120g 4 2 oz without battery Warranty Triplett Jewell Instruments extends the following warranty to the original purchaser of these goods for use Triplett warrants to the original purchaser for use that the products sold by it will be free from defects in workma...