CONTROL BUTTONS 

 

1.

 

Short press the 

▼SET

 button to silence the beeper (when it is 

sounding) or to disable/enable the alarm beeper. This button is 
also used as a down arrow to change the high and low Alarm 
threshold values in the Alarm Setup mode. 

 

2.

 

Long press the 

▼SET

 button to enter the Alarm Setup Mode (See 

Alarm Setup section). 

 

3.

 

Short press the 

 UNIT button to change the unit of measure 

(PPM or mg/m³) or to use it as an up arrow to set the alarm 
threshold values in the Alarm Setup mode. 

 

SAFETY 

 

Do not store or use the instrument in an environment 

where corrosive gas is present. Do not obstruct the sensors 

when in use. 

Use only the supplied lithium‐ion battery to power the meter. 

 

Use only the supplied AC adapter/battery charger to charge the lithium‐
ion battery. 

 

BATTERY CHARGE and REPLACEMENT 

 

1.

 

When the battery requires charging, plug the supplied battery 

charger into the meter (left side, under flap) and to a source of 
AC power. A full charge requires 2 hours. 

 

2.

 

To replace the battery, open the rear battery compartment and 

replace the Polymer lithium‐ion battery (7.4V 1300mAh). Re‐
assemble the meter before use. 

 

 
 
 
 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for FM260

Page 1: ...latile Organic Compounds TVOC Tester Introduction Thank you for selecting the Triplett FM260 The FM260 measures HCHO formaldehyde and TVOC Total Volatile Organic Compounds www GlobalTestSupply com Fin...

Page 2: ...logy High accuracy measurements Backlit LCD display Real time display of HCHO formaldehyde concentration in air Real time display of TVOC Total Volatile Organic Compounds concen tration in air Two uni...

Page 3: ...inactivity Press any function button to prevent the meter from powering off the auto power off timer will be then be reset The APO display symbol reminds the user that Auto Power OFF is always active...

Page 4: ...SET to silence the alarm beeper when it is sounding or to disable the beeper entirely When disabled the displayed beeper symbol is switched off ALARM SETUP HCHO only Low Alarm Setup 1 Long press the S...

Page 5: ...t store or use the instrument in an environment where corrosive gas is present Do not obstruct the sensors when in use Use only the supplied lithium ion battery to power the meter Use only the supplie...

Page 6: ...llection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of lif...

Page 7: ...Accuracy 5 FS Response Time 2 seconds Operating Temperature 0 C to 40 C 32 to 104 F Storage Temperature 10 C to 60 C 14 to 140 F Power Supply Rechargeable Polymer lithium ion battery 7 4V 1300mAh Batt...

Page 8: ...apply to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as in our sole judgment to injure their stability or...

Reviews: