Potential sources for TVOCs include paints, finishes, adhesives, cigarette 
smoke, pesticides, personal care products, car exhaust, new furnishings, 
wall coverings, household cleansers, and cooking fuels. Chemicals 
include: Acetone, Ethylene Glycol, Formaldehyde, Xylene, 1,3

butadiene, 

Tetrachloroethene, Hydrogen Sulfide, Ammonia, Toluene, Benzene, 
Methylene Chloride, Perchloroethylene, and MTBE. 
 
 

Features 

  

 

 

Fuel Cell Formaldehyde Sensor Technology   

 

High accuracy measurements   

 

Backlit LCD display   

 

Real

time display of HCHO (formaldehyde) concentration in air  

 

Real

 time display of TVOC (Total Volatile Organic Compounds) concen

tration in air  

 

Two unit selections (PPM, mg/m³)  

 

Audio

visual High and Low Alarms for HCHO  

 

Auto power off 

Description 

 

 
METER DESCRIPTION 

 

1.

 

HCHO sensor (front) 

 

2.

 

AC Adaptor jack (under flap) 

 

3.

 

Down arrow and Alarm Setup button 

 

 

4.

 

Battery compartment (rear) 

 

5.

 

ON‐OFF button (also used in Alarm Setup) 

 

6.

 

Up arrow and UNIT selection button 

 

7.

 

Backlit Display 

 

8.

 

TVOC sensor (rear) 

            

            

            

            

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Summary of Contents for FM260

Page 1: ...latile Organic Compounds TVOC Tester Introduction Thank you for selecting the Triplett FM260 The FM260 measures HCHO formaldehyde and TVOC Total Volatile Organic Compounds www GlobalTestSupply com Fin...

Page 2: ...logy High accuracy measurements Backlit LCD display Real time display of HCHO formaldehyde concentration in air Real time display of TVOC Total Volatile Organic Compounds concen tration in air Two uni...

Page 3: ...inactivity Press any function button to prevent the meter from powering off the auto power off timer will be then be reset The APO display symbol reminds the user that Auto Power OFF is always active...

Page 4: ...SET to silence the alarm beeper when it is sounding or to disable the beeper entirely When disabled the displayed beeper symbol is switched off ALARM SETUP HCHO only Low Alarm Setup 1 Long press the S...

Page 5: ...t store or use the instrument in an environment where corrosive gas is present Do not obstruct the sensors when in use Use only the supplied lithium ion battery to power the meter Use only the supplie...

Page 6: ...llection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household waste The user is obligated to take end of lif...

Page 7: ...Accuracy 5 FS Response Time 2 seconds Operating Temperature 0 C to 40 C 32 to 104 F Storage Temperature 10 C to 60 C 14 to 140 F Power Supply Rechargeable Polymer lithium ion battery 7 4V 1300mAh Batt...

Page 8: ...apply to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as in our sole judgment to injure their stability or...

Reviews: