background image

 
 

Changing the Units of Measure 

 

 

Press 

and hold the R button until the word ‘Unit’ appears. 

 

 

Now short press the power button to change the units for the 
selected measurement mode. 

 

 

Short press 

 to save the selection and move to the 

secondary function, if applicable (temperature, for example). 
Short press the power button to change the secondary function 
units, if applicable, and then short press 

 to save. 

 

 

See units list below: 

 

o

 

Sound dB 

o

 

Temperature units oC, oF (for air, dew point, wet bulb, 
heat index, and Type K) 

o

 

Light units 

Foot-candles, LUX 

 

Reversible Backlight LCD 

 

The LCD display automatically reverses its presentation 
orientation depending on measurement mode. This is to match the 
display orientation with the selected sensor mode (light or 
environmental measurements such as Wet bulb temperature). 
 
The LCD is equipped with backlighting for easier viewing, 
especially in dimly lit areas. With the meter powered ON, short 
press the power button to turn ON the backlight. The backlight will 
power OFF after several seconds. 

 
 
 
 
 
 
 

Display Hold 

 

Short press the H (Hold) button to freeze and unfreeze the displayed 
reading. The Display Hold mode is not operational when using the MAX-
MIN Recording mode. 

Summary of Contents for 614395003227

Page 1: ...Environmental Meter This instrument measures Sound Level dBA Light Relative Humidity with Air temperature Dew Point temperature Web bulb temperature Type K temperature external probe and Heat Index temperature The backlit LCD includes primary and secondary displays plus a variety of intuitive status indicators ...

Page 2: ...x temperature and Type K temperature with external probe connected MAX MIN Recording Display Hold freezes displayed reading for convenience Compact light weight easy to use ergonomic design with lanyard Backlit LCD automatically reverses orientation to match selected sensor mode Description METER DESCRIPTION 1 Sound Level Microphone 2 Type K Thermocouple Input 3 LCD Display 4 Display Hold Mode But...

Page 3: ...er approximately 10 minutes of inactivity Note that APO does not function while the meter is in the MAX MIN Recording mode short press the R button to access the MAX MIN Recording mode Selecting the Operating Mode Long press the M Mode button to scroll through the list of functions When the desired mode is displayed release the button See display icons with brief descriptions below dbSound Level d...

Page 4: ...x and Type K o Light units Foot candles LUX Reversible Backlight LCD The LCD display automatically reverses its presentation orientation depending on measurement mode This is to match the display orientation with the selected sensor mode light or environmental measurements such as Wet bulb temperature The LCD is equipped with backlighting for easier viewing especially in dimly lit areas With the m...

Page 5: ...ress and hold the R button to exit the Recording mode Measurement Modes Sound Level Measurement 1 With the meter ON press and hold the M Mode button until db is displayed then release the button 2 The meter will stard measuring the sound in dB Light Measurements Press and hold the M button until LigHt is displayed then release Hold the meter so that the source of light fully encompasses the light ...

Page 6: ...ove power from the meter 2 Remove the flat head screw that secures the battery compartment at the back of the meter 3 Open the battery compartment and replace the three 3 1 5V AAA batteries observing correct polarity Re assemble the meter before use Safety Please dispose of batteries responsibly never dispose of batteries in a fire batteries may explode or leak If the meter is not to be used for 6...

Page 7: ...me in contact with any of the sensors Specifications General Display Backlit LCD 3 0 x 3 5 cm 1 18 x 1 38 Sound Level Electric condenser microphone Light sensor Cosine color corrected photo diode Air Temperature sensor PT1K ohm RTD internal sensor Relative Humidity sensor Capacitance sensor Measurements Sound Level Relative Humidity with Air Temperature Light Dew Point Wet Bulb Heat Index and Type...

Page 8: ... x 1 0 inch Sound Level dBA Meter Measurement 35 130 dB Range Resolution 0 1 dB Function Data hold Record Max Min Accuracy Characteristics of A frequency weighting network 23 5 meet IEC 61672 2013 class 2 Under 94 dB input signal the accuracy is The above spec are tested under the Environment RF Field Strength than 3 V M frequency less than 30 MHz only ...

Page 9: ...0 to 50 0 1 1 2 C F 32 to 122 0 1 2 5 F Light automatic ranging Lux 0 to 2 200 1 1 800 to 20 000 10 5 rdg 8dgts Ft cd 0 to 204 0 0 1 170 to 1 860 1 Dew Point Temperature Unit Range Resolution Accuracy C 25 3 to 49 0 0 1 Calculated from temperature and F 13 5 to 120 0 0 1 humidity readings Wet Bulb Temperature C 5 4 to 49 0 0 1 Calculated from temperature and F 22 2 to 120 0 1 humidity readings Hea...

Page 10: ...ts to the original purchaser for use that the products sold by it will be free from defects in workmanship and material for a period of 1 one year from the date of purchase This warranty does not apply to any of our products which have been repaired or altered by unauthorized persons in any way or purchased from unauthorized distributors so as in our sole judgment to injure their stability or reli...

Reviews: