![Triple Play Communications AMP-1030P User Manual Download Page 33](http://html1.mh-extra.com/html/triple-play-communications/amp-1030p/amp-1030p_user-manual_1163845033.webp)
33
Table 9.0-3 - Optical Power Meter Specifications
Parameter
Minimum
Typical
Maximum
Optical Input Dynamic Measurement Range
1
-45 dBm
+10 dBm
Optical Output Dynamic Measurement Range
1
-35 dBm
+20 dBm
Resolution
±0.01 dB
Relative Accuracy/Linearity
±0.1 dB
Absolute Accuracy
±1.0 dB
Note 1: This 45 dB dynamic range can be shifted lower or higher based on the customer’s desired range.
Table 9.0-4 - Electrical, Mechanical, and Environmental Specifications
Parameter
Minimum
Typical
Maximum
Power Supply Voltage
+5V
Power Supply Interface
USB and/or
AC/DC Adapter
Operating Current (bias current for 30dB gain)
460 mA
490 mA
Operating Current (max bias current)
575 mA
600 mA
USB Communications Interface
USB 2.0
Ethernet Communications Interface
1
10/100BaseT
USB User Platform
Windows GUI
Ethernet User Interface (ex. Chrome, Firefox, IE)
HTML Browser
Optical Connectors (input and output)
FC/PC
Operating Temperature Range
0 °C
40 °C
Storage Temperature Range
-40 °C
85 °C
Dimensions
6” x 2.5” x 1.25”
Note 1: The software Interface Control Document can be provided so a custom control/status interface can be developed if desired
10.0
Mechanical Dimensions
Figure 10.0-1 - AMP-1030P Module Mechanical Dimensions