VOMP 600

I n s t a l l a t i o n ,   O p e r a t i o n ,   &   M a i n t e n a n c e   M a n u a l

9

www.trioniaq.com

Figure 2 - System Performance Curve

Sta

tic

 Pr

es

su

re

St

at

ic 

Pr

es

su

re

Summary of Contents for Air Boss VOMP 600

Page 1: ...T R I O N w w w t r i o n i a q c o m Air Boss VOMP 600 Vertical Oil Mist Precipitator READ AND SAVE THESE INSTRUCTIONS Installation Operation Maintenance Manual...

Page 2: ...III Introduction and Operation 4 IV Pre Installation Considerations 4 V Unit Location 4 VI Inspection and Installation 5 Location and Mounting 5 Ductwork 5 Piping 5 Wiring 5 VII Operation 5 VIII Care...

Page 3: ...r consequential damage with respect to property whether as a result of breach of warranty neglect or otherwise THE WARRANTIES AND LIABILITIES SET FORTH ARE IN LIEU OF ALL OTHER WARRANTIES AND LIABILIT...

Page 4: ...late filtration it may also be used for the filtration of dry particulate IV INTRODUCTION AND OPERATION EXPLANATION HOOD AND DUCT DESIGN The effectiveness of the installation is first dependent upon t...

Page 5: ...ervoir the piping must be adequately trapped to overcome the negative pressure inside the unit cabinet and thereby prevent air being drawn through the drain WIRING Refer to the applicable wiring diagr...

Page 6: ...h CLEANING The ionizing collecting cell impinger and the metal mesh filter require periodic cleaning Hot water 140 160 F 60 71 C and a good detergent safe for use on aluminum should be used TRION s Tr...

Page 7: ...TES PROPERLY SUPPLY VOLTAGE PRESENT AT UNIT MOTOR DOES NOT OPERATE SUPPLY VOLT AGE PRESENT AT UNIT MOTOR OPERATES INTERMITTENTLY SUPPLY VOLTAGE PRESENT AT UNIT MOTOR OPERATES WITH LITTLE OR NO AIR VOL...

Page 8: ...VOMP 600 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 8 www trioniaq com Figure 1 VOMP600 Outline...

Page 9: ...VOMP 600 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 9 www trioniaq com Figure 2 System Performance Curve Static Pressure S t a t i c P r e s s u r e...

Page 10: ...VOMP 600 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 10 www trioniaq com Figure 3 Wiring Schematic 120V 60Hz...

Page 11: ...VOMP 600 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 11 www trioniaq com Figure 4 Wiring Schematic 240V 60Hz...

Page 12: ...805 002 Venturi Insulator 14 14 12 226555 001 High Voltage Ground Plate 37 37 13 342836 002 Ground Electrode not shown 4 4 14 342834 001 Spike Blade 5 5 15 220107 118 Spacer Spike not shown 8 8 16 220...

Page 13: ...VOMP 600 I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 13 www trioniaq com Figure 6 Exploded Parts View...

Page 14: ...Form No 151345 001 Rev 10 18 TRION 2018 All Rights Reserved TRION 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com...

Reviews: