Maintenance -
How to Maintain Your Air Cleaner
The media filter cartridge in your air cleaner must be replaced periodically. The
frequency of filter replacement is best determined by visual examination. On average,
filter cartridges with normal usage should be replaced as follows:
MERV 8 Filters -
Replace every 9 - 12 months
MERV 11 Filters -
Replace every 4 - 6 months
Steps for replacing filter cartridge
1. Open access door by pulling the handle. Remove door completely.
2. Pull used filter straight out of cabinet and place to side.
3. Remove new filter cartridge from plastic bag and save the bag.
4. Slide new filter cartridge into cabinet with “AIR-FLOW” arrow pointing in the
direction of airflow.
5. Replace door and place used filter in plastic bag for easy disposal.
Replacement Filter Cartridges for your Media Air Cleaner
Remember, periodic inspection and replacement of your filter will ensure high
efficiency air cleaning. Contact your HVAC dealer for replacement filter cartridges.
AIR CLEANER
MODEL
FILTER
CARTRIDGE SIZE
MERV 8 FILTER
CARTRIDGE
PART NUMBER
MERV 11 FILTER
CARTRIDGE
PART NUMBER
FILTERS
PER
CARTON
AIR BEAR
SUPREME 2000
(20”X25”)
19/3/4”X24-1/4”X4-15/16”
255649-102 259112-102 3
AIR BEAR
SUPREME 1400
(20”X20”)
19/3/4”X20-3/4”X4-15/16”
255649-103 259112-103 4
AIR BEAR
SUPREME 1400
(16”X25”)
15/3/4”X24-1/4”X4-15/16”
255649-105 259112-105 3
AIR BEAR CUB
(16”X25”)
15/3/4”X24-1/4”X3-1/16”
255649-101 259112-101 6
8