Installation -
Physical Installation
The air cleaner cannot be installed with the access door facing down. The section
entitled
Typical Mounting Positions
(page 4) shows examples of proper air cleaner
mounting with a variety of furnace installations.
Prior to Installing this Product
1. Read rules and instructions carefully for safe operation. Failure to follow them could
damage the product or cause a hazardous condition.
2. Check the ratings given on the product to make sure it is suitable for your
application.
3. Remove the old furnace filter and discard.
4. The air cleaner cannot remove existing dirt from the blower and ducts. Clean the
area thoroughly before beginning installation.
NOTE: The following is a typical installation of the air cleaner on a highboy
furnace. You may have to alter the installation to fit your specific application.
5. Locate the cabinet in the cold air return duct such that all of the return air flows
through the unit. If the furnace and air cleaner openings are different, use a
transition.
6. Mounting holes are provided in the air
cleaner cabinet for ductwork attachment.
The .140” diameter holes are sized for #8
sheet metal screws, or 1/8” rivets. If the
adjoining ductwork is flanged, install the
screws with the screw heads inside the
cabinet, to prevent damage to the filter
cartridge during removal and installation.
7. Remove the plastic bag from the filter
cartridge and replace filter cartridge in
cabinet.
8. After the unit has been secured, seal
seams air tight with duct tape or caulking.
Reinstall access door to ensure a tight seal.