AMPLIFIER ENABLE (WATCHDOG) RELAY OUTPUT
An internal relay may be used to enable external amplifiers when the controller has
powered up correctly and the system and application software are ready. The amplifier
enable is a single pole solid state relay with a normally open “contact”. The enable
relay contact will be open circuit if there is no power on the controller OR an axis
error exists OR the user program sets it open with the WDOG=OFF command.
0
0
ETHERCAT DRIVES WILL BE ENABLED VIA THE ETHERCAT NETWORK SO THE
“AMPLIFIER ENABLE” CONNECTION IS NOT NORMALLY REQUIRED.
ALL NON ETHERCAT STEPPER AND SERVO AMPLIFIERS MUST BE INHIBITED
WHEN THE AMPLIFIER ENABLE OUTPUT IS OPEN CIRCUIT.
An additional safety relay may be required so as to meet machine safety approvals.