CLEAR to start over. The scale prompts ” S/N OK?” and displays the new serial
number. Repeat Step 2.
4. The scale prompts ” Set Code OK?” and displays the current setting code value.
5. Press the ENTER (Yes) key to accept the displayed setting code or press the CLEAR
(No) key to change the setting code.
Note:
If
“Yes”
is selected, the scale exits the Setup Menu. If
“No”
is selected, the
message “Enter Set Code:” appears in the display.
Using the numeric keys, enter the setting code obtained from your dealer. Push ENTER when
finished or CLEAR to start over. The scale prompts ” Set Code OK?” and displays the new setting
code. Repeat Step 5.
6.3 CALIBRATION
MENU
Your TS-70MC / MCI scale ships from the factory fully calibrated. There is no need to calibrate the
scale unless you feel that it has become inaccurate. It is a good idea to check the calibration of
your scale from time to time with a precision test weight. Triner recommends that you perform a
new calibration on your digital scale at least once a year.
The TS-70MC / MCI scale may be calibrated using precision test weights of 4 lb and 50 lb.
1. Enter the Calibration Mode by pressing and holding the Parcel Post (6) key while turning on the
scale. When the message “Calibration? Y/N” appears on the screen, you are in Calibration
Mode and you may release the Parcel Post (6) key.
2. Press the ENTER (Yes) key to enter the calibration mode. The scale displays the message “C
0 PR ZERO”.
3. Remove all items from the scale’s platter and then press the ZERO SCALE key to zero the
scale. The scale displays the message “C 0 PR ENTER”.
4. Press the ENTER key to save the zero point value. The scale displays the message “C 4 “.
5. Place the 4 lb test weight(s) onto the scale’s platter. When the weight stabilizes, the scale
displays the message “C 4 PR ENTER”.
6. Press the ENTER (Yes) key to save the 4 lb calibration value. The scale displays the message
“C 50 “.
7. Place the 50 lb test weight onto the scale’s platter. When the weight stabilizes, the scale
displays the message “ PR ENTER”.
8. Press the ENTER (Yes) key to save the 50 lb calibration value. The scale then displays the
message “Calibration End”.
9. Turn OFF the scale then turn back ON to resume normal operation.
6.4 ANALOG TO DIGITAL CONVERSION (ADC) DIAGNOSTIC MENU
This menu is reserved for Triner technical personnel only.