3.  Using the numeric keys, enter the desired markup percentage. The scale asks if the 

percent markup for the displayed rate category is OK. Repeat Step 2. 

 

Note:  

If the desired markup percentage is less than 10, you must press the ENTER 

key. Otherwise, if the desired markup percentage is 10 or greater, the scale 
automatically enters the value for you. 

 

4.  Repeat Steps 2 and 3 for all rate categories listed. 

 

6.2.3 BUZZER 

ENABLE/DISABLE 

 

This function is used to enable or disable the audible tone heard when a key is pressed. 

 

1.  Enter the Setup Menu Mode as described above and press the ENTER key until the 

scale prompts ” Buzzer OK?” and displays the current status (ON/OFF) of the buzzer. 

 

2.  Press the ENTER (Yes) key to accept the displayed buzzer status or press the CLEAR 

(No) key to change the buzzer status.  

 

Note:  

If 

“Yes”

 is selected, the scale proceeds to Normal Operating Mode.  If 

“No”

 is 

selected, the status toggles between ON and OFF. 
 

6.2.4  INTERFACE TYPE (TS-70MCI ONLY) 
 

This function is used to program your postage meter interface type. 
 

NOTE:

 The PB Direct Fox interface type requires a valid serial number and setting code in 

order to work properly. If you do not have these codes, contact your dealer to activate this 
interface. 

 

1.  Enter the Setup Menu Mode as described above and push the ENTER (yes) key until 

the scale prompts ” Interface OK?” and displays the current interface setting  
(0-1). 

 

The interface types currently available include the following: 

• 

Non-Interfaced (0) 

• 

PB Direct Fox (1) 

• 

Receipt Printer (2) 

 

2.  Press the ENTER (Yes) key to accept the displayed interface type or press the CLEAR 

(No)  key to change the interface type.  

 

Note:  

If 

“Yes”

 is selected, the scale proceeds to the Serial Number and Setting Code 

setup if PB Direct Fox is chosen. (Otherwise, the scale exits the setup menu.)  If 

“No”

 is 

selected, the message “Interface (0-1) ?” appears in the display. 

 

3.  Using the numeric keys, enter your interface type (0-1). The scale prompts ” Interface 

OK?” and displays the current interface type. Repeat Step 2. 

 
To program your serial number and setting codes, refer to the following: 
 
1.  The scale prompts ” S/N OK?” and displays the current serial number value. 

 

2.  Press the ENTER (Yes) key to accept the displayed serial number or press the CLEAR 

(No) key to change the serial number.  

 

Note:  

If 

“Yes”

 is selected, the scale proceeds to Step 4.  If 

“No”

 is selected, the 

message “Enter S/N: ” appears in the display. 

 

3.  Using the numeric keys, enter the last ten digits of the scale’s serial number found on 

the label attached to the scale. Do NOT enter leading zeroes. Example: If the tag reads 
550050000268, you would only need to enter 50000268. Push ENTER when finished or 

 

Page 6-2 

Summary of Contents for TS-70MC

Page 1: ...TS 70MC MCI Rate Computing Scale Operation Manual Revision 1 2 June 9 2006...

Page 2: ...cale Mfg Co Inc Contents subject to change without notice Triner Scale Mfg Co Inc 8411 Hacks Cross Road Olive Branch MS 38654 4010 662 890 2385 800 238 0152 Fax 662 890 2386 info trinerscale com www t...

Page 3: ...he equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions manual may c...

Page 4: ...3 3 3 3 General Scale Operation 3 4 3 3 1 System Prompts 3 4 3 3 2 Mailing or Shipping an Item 3 4 3 3 3 Weighing a Letter or Package 3 4 3 3 4 Selecting a Class of Service 3 4 3 3 5 Entering a ZIP Co...

Page 5: ...e UPS B 1 B 1 3 Federal Express FEDEX B 1 B 1 4 Special Services B 1 B 1 5 Functions B 1 Appendix C Rate and Special Service Abbreviations C 1 C 1 Rate Abbreviations C 1 C 2 Special Services Abbreviat...

Page 6: ...and convenient place so it will be available if you have questions concerning the opera tion of the scale VERY IMPORTANT Before you use the TS 70MC MCI for calculating shipping rates the first three...

Page 7: ...rect sunlight wind or dust 5 Do not place the scale in an area with vibrating equipment Step 2 Install the AC Adapter 1 After placing the scale in its area of use locate the AC Adapter 2 Connect the f...

Page 8: ...XICO UPS NEXT DAY UPS 2ND DAY GROUND RESID L UPS GROUND COMM L PRIORITY FED EX STD FED EX 2ND DAY INSURE PRIORITY POST DEL CON PRINT TRINER SCALE MEMPHIS TN USA ACCURATE AROUND THE WORLD SINCE 1897 RA...

Page 9: ...ate Press once for commercial rate Press again for residential rate Press the Letter 1 key to switch to the Letter rate Second Day Air Letter Package Selects the Second Day Air Package rate Press once...

Page 10: ...IP code has been entered If a one or two digit code has been entered using the ENTER key the scale assumes a new zone has been entered 3 2 2 3 CLEAR NO KEY The CLEAR RESET key is used to clear the cur...

Page 11: ...3 3 2 Press a rate key to select the mailing or shipping method Refer to Section 3 3 4 for more information on selecting the desired class of mail 3 If the method of shipment and or the weight of the...

Page 12: ...ts you for a three digit numeric country code Refer to the Country Code Chart in Appendix E and enter the three digit destina tion country code If an invalid country code is entered the scale displays...

Page 13: ...LE 1 Press the 1st Priority 5 key No further action is necessary CLASS CARRIER ZONE CTRY LB OZ RATE PRIORITY 5 1 0 8 3 95 3 Priority Mail Over 5 Pounds ACTION DISPLAY EXAMPLE 1 Press the 1st Priority...

Page 14: ...Using the numeric keys enter the country code from Appendix D In our example we will choose Canada which has a country code of 237 You could also press the CANADA key CLASS CARRIER ZONE CTRY LB OZ RA...

Page 15: ...this example we will use ZIP code 123 CLASS CARRIER ZONE CTRY LB OZ RATE ZIP ZONE 123 1 1 8 3 00 3 The screen now shows the UPS 2nd Day Air Package rate CLASS CARRIER ZONE CTRY LB OZ RATE 2DP COM 206...

Page 16: ...In this example we will use ZIP code 123 CLASS CARRIER ZONE CTRY LB OZ RATE ZIP ZONE 123 1 1 8 3 00 3 The screen now shows the FedEx Standard Overnight Package rate CLASS CARRIER ZONE CTRY LB OZ RATE...

Page 17: ...2 Press the ZERO SCALE key 3 Press the PIECE COUNT key The scale prompts you to place a 10 piece sample count on the scale 4 Place the 10 piece sample count on the scale The scale prompts you to pres...

Page 18: ...ZIP code Once all three digits are entered the scale prompts ZIP Code OK and displays the current ZIP code Repeat Step 2 6 2 2 HANDLING CHARGE This function is used to program a percentage markup for...

Page 19: ...rface 1 Enter the Setup Menu Mode as described above and push the ENTER yes key until the scale prompts Interface OK and displays the current interface setting 0 1 The interface types currently availa...

Page 20: ...n test weights of 4 lb and 50 lb 1 Enter the Calibration Mode by pressing and holding the Parcel Post 6 key while turning on the scale When the message Calibration Y N appears on the screen you are in...

Page 21: ...ction 2 Set Clear The user is required to press the Set Meter ENTER key to transmit the postage to the meter for each transaction The user is also required to press the Set Meter again to clear the la...

Page 22: ...le Keypad OVER CAPACITY ANNUNCIATION 103 of Full Scale Capacity NON LEGAL FOR TRADE OPERATING TEMPERATURE RANGE 32 F to 104 F 0 C to 40 C LEGAL FOR TRADE OPERATING TEMPERATURE RANGE 41 F to 95 F 5 C t...

Page 23: ...ntial 2nd Day Air Letter Package Commercial and Residential Ground Package Commercial and Residential B 1 3 FEDERAL EXPRESS Priority Overnight Letter Package Commercial and Residential Standard Overni...

Page 24: ...PS 2nd Day Air Package Residential 2DP RES UPS Ground Commercial GRD COM UPS Ground Residential GRD RES Fed Ex Priority Letter Commercial FPL COM Fed Ex Priority Letter Residential FPL RES Fed Ex Prio...

Page 25: ...ile 343 China 344 Colombia 345 Comoros 346 Congo Republic of 347 Corsica 348 Costa Rica 349 Cote d Ivoire Ivory Coast 350 Croatia 351 Cuba 352 Cyprus 353 Czech Republic 354 Denmark 355 Djibouti 356 Do...

Page 26: ...airn Island 455 Poland 456 Portugal 457 Qatar 458 Reunion 459 Romania 460 Russia 461 Rwanda 462 St Christopher Nevis 463 St Helena 464 St Lucia 465 St Pierre Miquelon 466 St Vincent Grenadines 467 San...

Page 27: ...511 Western Samoa 512 Yemen 513 Congo Dem Republic of 514 Zambia 515 Zimbabwe Page D 3...

Page 28: ...lgium BELGIUM Gabon GABON Belize BELIZE Gambia GAMBIA Benin BENIN Republic of Georgia GEORGIA Bermuda BERMUDA Germany GERMANY Bhutan BHUTAN Ghana GHANA Bolivia BOLIVIA Gibraltar GIBRALTA Bosnia Herzeg...

Page 29: ...li MALI Somalia SOMALIA Malta MALTA Spain SPAIN Martinique MARTINIQ Sri Lanka SRI LANK Mauritania MAURITAN St Christopher Nevis ST CHRI Mauritius MAURITIU St Lucia SAINT LU Mexico MEXICO St Pierre Miq...

Page 30: ...Emirate UNITED A Uruguay URUGUAY Uzbekistan UZBEKIST Vanuatu VANUATU Vatican City VATICAN Venezuela VENEZUEL Vietnam VIETNAM Wallis Futuna Islands WALLIS Western Samoa W SAMOA Yemen YEMEN Zambia ZAMB...

Page 31: ...ystem reside on one Rate Card which is removable from the scale for reprogramming purposes 1 Turn the scale s AC power switch to the off position 2 Remove the Rate Card cover from the right hand side...

Page 32: ...that the special service is not valid for the class of mail selected Invalid Service Indicates that the special service is not valid with the current special service s selected G 1 2 METER SET TRIP ER...

Page 33: ...g on the platter remove item from platter NOTE Only when scale is in NTEP mode REPLACE PLATTER Scale is switched on without platter re install platter NOTE Only when scale is in NTEP mode Setting Code...

Page 34: ...for warranty service should the Triner Scale label or logo or the serial number be removed or the product fail to be properly maintained or fail to function properly as a result of misuse abuse impro...

Reviews: