34
Installation Guide for SecureMesh WAN® Gateway 2 - PL-0073A
Note:
It is recommended to remove the gasket in order to
insert the RJ45 connector.
17. Mate the RJ45 connector to JP2.
18. Repeat steps 15 and 16 for the Cat6 cable that connects to the PSE. It should
connect to JP1.
19. Slide the black gasket back into place.
Note:
Ensure both RJ45 connectors are fully mated and
latched.
20. Double check that the nut on the surge suppressor's grounding stud is tight.
21. Close the surge suppressor door and tighten the latching screw.
22. Mate the Cat6 DSC to the bulkhead RJ45 connector on the bottom of the
GATE-2000.
23.
Note:
Before connecting the DSC, make sure the end of the
plastic locking tab on the RJ45 is inside the body of the
connector. If the locking tab is not inside, it can snap off when
the coupling nut is tightened. Also, ensure the strain relief nut
is not tight and that the Cat6 cable is free to move.
Note:
Make sure you align the mating halves of the RJ45
connectors before inserting the connector.