![Trikdis G16T 3 Series User Manual Download Page 24](http://html1.mh-extra.com/html/trikdis/g16t-3-series/g16t-3-series_user-manual_1162607024.webp)
24
July, 2018
GSM communicator G16T_3xxx
Test communicator performance
Protegus
1.
Activate an event in the control panel, and make sure that the event arrives to the ARC or is received in the mobile
application:
- Arm/Disarm alarm system
- trigger any zone when control panel is in ARM mode
2.
Verify that events have been received in the ARC and/or Protegus app.
3.
To test communicator inputs, activate it and make sure that the correct messages arrives to recipients.
4.
To test the communicator output, please activate it remotely.
5.
To test Remote control feature, using Protegus service Arm/Disarm system, check if commands were performed.
Manual firmware update
The communicator firmware can be updated or changed manually. After an update, all the previous communicator parameters
will remain the same.
When writing firmware manually, it can be changed to a newer or older version. To update:
1)
Run TrikdisConfig.
2)
Connect the communicator via USB cable to the computer or connect to the communicator remotely.
If newer firmware version exists, the software will offer to download the newer firmware version file.
3)
Select the menu branch Firmware.
Note:
If there is an installed antivirus software on your computer, it might block automatic firmware update option.
In this case you must reconfigure your antivirus software.
4)
Press Open firmware and select the required firmware file.
If you do not have the file, the newest firmware file can be downloaded by registered user from www.trikdis.com ,
under the download section of the G16T_3xxx communicator.
5)
Press Update [F12].
6)