21
July, 2018
GSM communicator G16T_3xxx
Remote control
Answers to the SMS commands can be customised in SMS answer text field.
List a phone number for remote control to a table Phone numbers for remote control. SMS text, that user receives after
sending a command (to receive an SMS answer message, the user access code must be correct).
5.5.1
SMS commands list
SMS Commands are used to remotely control the communicator.
As access cod
e use “Administrator code” or “Installer code”,
“_” represents a space.
SMS command structure:
AccessCode_Command_Data
.
Command
Data
Description
INFO
Information about the communicator request. The response will include
communicator type, IMEI number, serial number and firmware version.
Ex.: 123456 INFO
RESET
Restart the communicator.
Ex.: 123456 RESET
OUTPUTx
ON
Turn on the output, where “x” represents output number 1 or 2.
Ex.: 123456 OUTPUT1 ON
OFF
Turn off the output, where “x” represents output number 1 or 2.
Ex.: 123456 OUTPUT1 OFF
PULSE tttt
Turn on the output for a number of seconds, where “x” represents output number
(1) and “tttt” a four-digit number representing pulse duration in seconds.
Ex.: 123456 OUTPUT1 PULSE=0002
CONNECT
Protegus=ON
Turn on Protegus cloud service
Ex.: 123456 CONNECT PROTEGUS=ON
Protegus=OFF
Turn off Protegus cloud service
Ex.: 123456 CONNECT PROTEGUS=OFF
IP=0.0.0.0:8000
Main server IP and Port
Ex.: 123456 CONNECT IP=192.120.120.255:8000
ENC=123456
TRK encryption key
Ex.: 123456 CONNECT ENC=123456
APN=Internet
APN name
Ex.: 123456 CONNECT APN=INTERNET
USER=user
APN user
Ex.: 123456 CONNECT USER=User
PASS=password
APN password
Ex.: 123456 CONNECT PASS=Password
CP=
Panel type from panel type list (1- Disabled; 2 – Interface DTMF).
Ex. (G16T assign to Interface DTMF): 123456 CONNECT CP=2
SIM card window
Ensure that the SIM cards are working, before using them.
If GPRS or 3G communication is required, ensure mobile data service is enabled.
For information, how to enable this service please contact your GSM service provider.