![Trigon Electronics Miniguard 100B Programming Manual Download Page 7](http://html1.mh-extra.com/html/trigon-electronics/miniguard-100b/miniguard-100b_programming-manual_1162559007.webp)
Page 7
Card Codes assigned to Specific Residents
Enter: #1 *123**13579# Assigns Resident 123's 1st Blank Position with Card Code of
13579.
Programming Number
Separators
Programming Terminator
Card Code
Defines as
Card Code
Resident Code
Enter: #1 *123*1*13579# Assigns Resident 123's 1st Card Code as 13579.
Enter: #1 *123*2*24680# Assigns Resident 123's 2nd Card Code as 24680.
Enter: #1 *123**44444#
Assigns Card Code of 44444 to 1st Blank Card Code position.
Enter: #2 *123*1#
Deletes Resident 123's 1st Card Code.
Enter: #2 *123#
Deletes all of Resident 123's Card Codes.
.
#
1
*
1
2
3
* *
1
3
5
7
9
#
Entry Codes assigned to Specific Residents
New! Entry Codes are now mixed variable length of 1 to 6 digits per.
Enter: #1 123**2468# Assigns Resident 123's 1st Blank Position with Entry Code of 2468.
Programming number
Separators
Programming Terminator
Entry Code
Resident Code
New! Multiple Entry Codes and Card Codes are allowed per Resident on special request.
Enter: #1 123*1*1357#
Assigns Resident 123's 1st Entry Code as 1357.
Enter: #1 123*2*2468#
Assigns Resident 123's 2nd Entry Code as 2468.
Enter: #2 123*1#
Deletes Resident 123's 1st Entry Code.
Enter: #2 123#
Deletes all of Resident 123's Entry Codes.
#