![Trigon Electronics Miniguard 100B Programming Manual Download Page 10](http://html1.mh-extra.com/html/trigon-electronics/miniguard-100b/miniguard-100b_programming-manual_1162559010.webp)
As always, you must be in programming mode to issue programming commands.
Assign a Function to a Tone
using command
9
: (out going calls placed from the unit)
9ft
Set function f (0 to 9) to tone t (0 to 9) for out going calls from unit.
Function (0 to 9)
Tone (0 to 9)
Programming number
Ie: 905
Sets function "0" (Cycle Gate-1 & Hangup) to Tone 5.
Assign a Function to a Tone
using command
9#
: (incoming calls answered by the unit)
9#ft
Set function f (0 to 9) to tone t (0 to 9) for calls answered by the
unit.
Ie: 9#05
Sets function "0" (Cycle Gate-1 & Hangup) to Tone 5.
Function (0 to 9)
Tone (0 to 9)
Programming number
Why disable a function? Some folks have Caller ID and may see the source phone number
of the line the unit is attached to. They may call the unit. They may latch a gate
open. So put a Seven everywhere that you want a function disabled. A better option is
to specify that the line attached to the unit has "Caller Id Blocked" set active for
that line on all calls placed by the unit. That way the owners or managers may still
call the unit, because they know the private phone number, and latch or unlatch the
gate, or do special functions without the worry of having residents fooling around with
their gate controls, etc.
Default “door” settings for resident.
“0” key grants entry to visitor.
“7” key denies entry to visitor.
“4” key allows resident to talk to visitor when T.E.D. is activated.
“#” key replays TED message if desired.
All of these are programmable using the “Detail Programming Tone Functions” on page 9.