As always, you must be in programming mode to issue programming commands.

Assign a Function to a Tone

using command

9

: (out going calls placed from the unit)

9ft

Set function f (0 to 9) to tone t (0 to 9) for out going calls from unit.

Function (0 to 9)

Tone (0 to 9)

Programming number

Ie: 905

Sets function "0" (Cycle Gate-1 & Hangup) to Tone 5.

Assign a Function to a Tone

using command

9#

: (incoming calls answered by the unit)

9#ft

Set function f (0 to 9) to tone t (0 to 9) for calls answered by the

unit.

Ie: 9#05

Sets function "0" (Cycle Gate-1 & Hangup) to Tone 5.

Function (0 to 9)

Tone (0 to 9)

Programming number

Why disable a function? Some folks have Caller ID and may see the source phone number
of the line the unit is attached to. They may call the unit. They may latch a gate
open. So put a Seven everywhere that you want a function disabled. A better option is
to specify that the line attached to the unit has "Caller Id Blocked" set active for
that line on all calls placed by the unit. That way the owners or managers may still
call the unit, because they know the private phone number, and latch or unlatch the
gate, or do special functions without the worry of having residents fooling around with
their gate controls, etc.

Default “door” settings for resident.

“0” key grants entry to visitor.
“7” key denies entry to visitor.
“4” key allows resident to talk to visitor when T.E.D. is activated.
“#” key replays TED message if desired.
All of these are programmable using the “Detail Programming Tone Functions” on page 9.

Page 10

9

n

n

9

#

n

n

Summary of Contents for Miniguard 100B

Page 1: ...ronics com 100 Made in Corona CA Uni 2010 Quickstart Keypad Programming Guide July 2010 Revision 1 1 Miniguard II Miniguard IID Miniguard 4D Miniguard 100B Miniguard 100BD Minipak Minipak WG Minipak 2...

Page 2: ...mode Default programming code for new universal board NOTE Enter Exits Programming Mode Change Program Access Code Command to set 3nnnn Where nnnn is the new 4 digit programming access code Programmin...

Page 3: ...responds with P l e a s es t a n db yw h i l eI c o n t a c t y o u r p a r t yf o r e n t r ya p p r o v a l T E D then places a call to the resident and announces the following T h i si sy o u r E l...

Page 4: ...Dialer Mode Option Options are n 0 with call progress false dial off verify dialtone off n 1 without call progress false dial off verify dialtone off n 2 with call progress false dial on verify dialt...

Page 5: ...ates the Resident Code from their Home Phone Number 5551212 is their specific Home Phone Number up to 16 digits The key terminates this Command Beep Beep means the Command was accepted or Long Tone me...

Page 6: ...rs in past products because the person programming is basically working blind To move the cursor left you must use the 0 key and move the cursor right until it wraps back to the the start of the line...

Page 7: ...d Code Enter 2 123 Deletes all of Resident 123 s Card Codes 1 1 2 3 1 3 5 7 9 Entry Codes assigned to Specific Residents New Entry Codes are now mixed variable length of 1 to 6 digits per Enter 1 123...

Page 8: ...00 PM 18 00 is six o clock 6 00 PM 3 1 0 0 1 0 2 2 3 3 0 1 View the Clock via unit display by going into programming mode and use command 3 Display current time as Year Month Date Hours Minutes Day w...

Page 9: ...refers to doing a gate access granted cycle on relay 1 2 or 3 Set Switch n refers to Macro Usage where the Switch can be defined to other func tions Engage Relay simply sets the relay active until th...

Page 10: ...latch a gate open So put a Seven everywhere that you want a function disabled A better option is to specify that the line attached to the unit has Caller Id Blocked set active for that line on all ca...

Page 11: ...Page 11...

Page 12: ...n Set Alarm Interval in 5 second periods Default 3 Page 10 8 n Set MG3 HF3 TA3 Passback options Default 0 Page 15 9nn Assign a Tone to a Function for when unit dials out normally Page 24 9 nn Assign a...

Page 13: ......

Reviews: