background image

PLASTIC LEVER

BREAK TAB AT

DOTTED LINE BY

TWISTING TOWARD

CENTER OF BASE.

USE SMALL-BLADED

SCREWDRIVER TO

PUSH PLASTIC LEVER

IN DIRECTION OF

ARROW.

C0144-00

FIGURE 7A. ACTIVATING THE TAMPER-RESIST FEATURE

FIGURE 6. SYNCHRONIZATION DIAGRAM (FOR MDL SERIES SYNC MODULES ONLY)

C1090-00

NOTE: Wiring shown for MDL Series Sync Module. For additional wiring configurations, see your sync module manual.

FACP #1

+

+

+

+

+

+

+

EOL 

(1)

}

}

}

}

HORN 

CONTROL

ZONE 1 

IN

ZONE 2 

IN

SLAVE 

IN





}

}

}

}

ZONE 1 

OUT

ZONE 2 

OUT

NAC 

SLAVE IN

SLAVE 

OUT

TEMP JUMP OFF

NAC 1

}

B+
B–

NAC 2

}

B+
B–

NAC 3

}

B+
B–

TO NEXT DEVICE 

OR EOL (1)

TO NEXT DEVICE 

OR EOL (1)

2 STYLE Y ZONES

(CLASS B)

MASTER

SOUNDER

BASE

SOUNDER

BASE

OPTIONAL

FIGURE 7B. REMOVING THE DETECTOR HEAD FROM THE BASE

SLOT

SLOT

C1082-00

Triga™ is a trademark of TRIGA Life Safety Systems, LLC. System Sensor® is a registered trademark of Honeywell International, Inc.

I56-3387TRG-009 

©2021. 4/22/2021

Summary of Contents for TR-B200S-WH

Page 1: ...gh volume setting 15 mA maximum at low volume setting SLC Electrical Ratings SLC Operating Voltage 15 to 32 VDC SLC Standby Current 300 μA maximum Sound Output High Volume Greater than 85 dBA minimum measured in a UL reverberant room at 10 feet 3 1m 24 Volts in continuous tone Low Volume Greater than 75 dBA minimum measured in a UL reverberant room at 10 feet 3 1m 24 Volts in continuous tone The s...

Page 2: ... the base without the use of a tool To activate this feature break the tab from the detector base as shown in Figure 7A Then install the detector To remove the detector from the base once the tamper resist feature has been activated insert a small bladed screwdriver into the slot from the top and press down on the lever see Figure 7B This allows the detector to be rotated counterclockwise for remo...

Page 3: ...C NAC OPTIONAL REMOTE ANNUNCIATOR MODEL RA400Z 100Z E O L A SEPARATE SYNCHRONIZATION MODULE MAY BE USED TO PROVIDE THE SYNCHRONIZATION PULSES HORN HORN STROBE UL LISTED COMPATIBLE CONTROL PANEL UL LISTED 24V POWER SUPPLY WHEN USING 24V CONSTANT POWER AUX POWER ADDITIONAL POWER SUPERVISION RELAYS AND MODULES WILL BE REQUIRED FOR PROVIDING SUPERVISION WHEN THE SOUNDER BASES ARE INACTIVE CLASS A OPTI...

Page 4: ...l wiring configurations see your sync module manual FACP 1 EOL 1 HORN CONTROL ZONE 1 IN ZONE 2 IN SLAVE IN ZONE 1 OUT ZONE 2 OUT NAC SLAVE IN SLAVE OUT TEMP JUMP OFF NAC 1 B B NAC 2 B B NAC 3 B B TO NEXT DEVICE OR EOL 1 TO NEXT DEVICE OR EOL 1 2 STYLE Y ZONES CLASS B MASTER SOUNDER BASE SOUNDER BASE OPTIONAL FIGURE 7B REMOVING THE DETECTOR HEAD FROM THE BASE SLOT SLOT C1082 00 Triga is a trademark...

Reviews: