Control module for PCA/TE one4all/PCD
For DIN rail 

modular

DIM DM 

Control with daylight sensor/3 channels

type  

 

modular

DIM DM

article number 

 

 

86454564

supply 

 – 

–  

via iX (intelligent extension)

input 

daylight sensor 

– 

1

 

switch manual/automatic 

– 

1

output 

control line iX (intelligent extension) 

– 

1

temperature 

permitted ambient temperature 

°C 

 +50

Expansion module for daylight linked control of the 
modular

DIM BASIC

 module. The daylight informa-

tion will be passed on from the modular

DIM

 

DM

 to 

the basic module to control up to three application-
specific luminaire groups. Simple programming of 
each independent luminaire group.

5-year guarantee

accessories 

sensor DAYLIGHT

article number 

86454586

The modular

DIM

 system includes an attractive and 

solid ceiling mounted sensor for the detection of 
sky brightness. Its sensing aperture is aligned in 
the direction of the daylight.

5-year guarantee

Packaging:

single packaged
box of 10

 

lux

CONTROL

 

modular

DIM

Packaging carton:

30 pc(s).

3

Data sheet 08/14-CO061-3  We reserve the right to make technical changes without prior notice.

60

30°

Ø 80

24

15

5

Ø 80

Glow-wire test

according to EN 60598-1 passed.

Summary of Contents for modularDIM SC

Page 1: ...t extension 1 temperature permitted ambient temperature C 0 50 The modularDIM BASIC control module is the basis of the modularDIM product range The three output channels can be controlled individually or together Simple installation since no programming is required Parallel connection of several switches enables user friendly dimming and ON OFF switching from several points The modularDIM BASIC co...

Page 2: ...ambient temperature C 0 50 Expansion module for modularDIM systems to control scenes Enables the recall and program ming of four light scenes via the modularDIM BASIC The switch inputs are SELV and any push to make switches can be used 5 year guarantee luxCONTROL modularDIM Switch inputs are safety low voltage SELV Any standard push to make switch may be used Packaging carton 1 pc s 2 Data sheet 0...

Page 3: ...odularDIM DM to the basic module to control up to three application specific luminaire groups Simple programming of each independent luminaire group 5 year guarantee accessories sensor DAYLIGHT article number 86454586 The modularDIM system includes an attractive and solid ceiling mounted sensor for the detection of sky brightness Its sensing aperture is aligned in the direction of the daylight 5 y...

Page 4: ...ls based on the galvanic isolation The modularDIM LC is designed as to build in unit for the integration into a switch cabinet This unit is easy to install Packaging carton 30 pc s type modularDIM LC article number 86457888 voltage V 220 240 frequency Hz 50 60 galvanic isolation spec 4000 V 2 min 6 mm SELV max output voltage V 30 permitted ambient temperature C 0 50 and to com mission because ther...

Page 5: ...ffort Therefore this important feature of the modularDIM LC gives now the opportunity to combine the modularDIM system with the common commercial of the shelf main rated presence detection PD units sensors PD 1 PD 3 potential free in order to the com contact because of the galvanic isolation modularDIM DM The modularDIM DM is an extension module powered directly by the modu larDIM BASIC module It ...

Page 6: ...m point is acknowledged by the flashing of the lighting source 5 For programming further channels repeat steps 1 4 6 Select the channel you wish to control via daylight management by selecting the appropriate channel or combinations of channels using the selector switch on the modularDIM DM module 0 25 50 500 LUX Artificial light Daylight Day I II III Programming of twilight set points The setting...

Page 7: ...D2 DA L N PCD 2 PCA 6 D1 DA D2 DA 3 4 7 D1 DA D2 DA L N TE one4all D1 DA D2 DA L N PCD modularDIM DM channel selector iX X2 AUTO S1 S2 S1 S2 X1 MAN Installation instructions To enable several operating points to be used several keys or switches are connected in parallel The maximum operating length of all keys as well as the light sensor may not be more than a max length of 100 m The DSI signal is...

Reviews: