background image

www.tridonic.com

9

Subject to change without notice. Information provided without guarantee.

Data sheet 04/22-EM115-12

Emergency lighting units

EM LED Light Engines

8. Miscellaneous

8.1 Black Box data recording

Recording of several parameters only accessable for Tridonic.

8.2 Additional information

Additional technical information at www.tridonic.com 

 Technical Data

The light source of this luminaire is not replaceable; when the light source 
reaches its end of life replace the whole luminaire. Lifetime declarations 
are informative and represent no warranty claim. No warranty if device was 
opened.

7. Optical properties

7.1 Anti panic

7.2 Escape route 

Light distribution

Light distribution

Max. spacing for >0.5 lux

1

Height

Centre to end

2

Centre to centre

3

Trans

Axial

Trans

Axial

2.5 m

3.85 m

3.80 m

10.90 m

10.85 m

3.0 m

3.80 m

3.75 m

11.90 m

11.90 m

3.5 m

3.80 m

3.80 m

12.90 m

12.90 m

4.0 m

3.70 m

3.70 m

13.90 m

13.85 m

5.0 m

3.55 m

3.50 m

14.90 m

14.90 m

6.0 m

3.10 m

3.05 m

15.10 m

15.05 m

All values for ta = 30 °C
Luminous flux: 200 lm

1

 Maintainance factor = 0.8, photometric data available on request

2

 Distance between module and wall

3

 Distance between two modules

-60°

-50°

-40°

-30°

-20°

-10°

10°

20°

30°

40°

50°

60°

70°

80°

90°

0

10

20

30

40

50

60

70

80

90

100

110

 

20

-20

40

60

80 100

-40

-60

-80

-100

0

-60°

-50°

-40°

-30°

-20°

-10°

10°

20°

30°

40°

50°

60°

70°

80°

90°

0

10

20

30

40

50

60

70

80

90

100

110

 

20

-20

40

60

80 100

-40

-60

-80

-100

0

rela

tiv

e int

ensity Iv

/Iv

,max

rela

tiv

e int

ensity Iv

/Iv

,max

Max. spacing for >1.0 lux

1

Height

Centre to end

2

Centre to centre

3

Trans

Axial

Trans

Axial

2.5 m

4.75 m

2.75 m

11.65 m

6.55 m

3.0 m

4.80 m

2.95 m

12.75 m

7.20 m

3.5 m

5.05 m

1.50 m

13.45 m

6.85 m

4.0 m

5.20 m

1.65 m

13.60 m

6.50 m

5.0 m

5.50 m

1.80 m

14.30 m

4.35 m

6.0 m

5.70 m

1.90 m

15.05 m

4.85 m

7.0 m

5.75 m

1.90 m

15.60 m

5.15 m

8.0 m

5.65 m

1.85 m

16.05 m

5.35 m

All values for ta = 30 °C
Luminous flux: 200 lm

1

 Maintainance factor = 0.8, photometric data available on request

2

 Distance between module and wall

3

 Distance between two modules

C0 / C90 / C180 / 270  

C0 / C180
C90 / C 270  

7.3 Spot

Light distribution

-60°

-50°

-40°

-30°

-20°

-10°

10°

20°

30°

40°

50°

60°

70°

80°

90°

0

10

20

30

40

50

60

70

80

90

100

110

 

20

-20

40

60

80 100

-40

-60

-80

-100

0

rela

tiv

e int

ensity Iv

/Iv

,max

Max. spacing for >0.5 lux / > 5 lux

1

Minimum 
illuminance

Height

Centre to end

2

Centre to centre

3

Trans

Axial

Trans

Axial

0.5

2.5 m

1.05 m

1.90 m

8.40 m

4.30 m

3.0 m

2.35 m

1.25 m

5.35 m

5.20 m

3.5 m

2.80 m

1.45 m

6.25 m

6.05 m

4.0 m

1.70 m

1.70 m

7.90 m

5.85 m

5.0 m

2.10 m

2.05 m

8.90 m

8.40 m

6.0 m

2.30 m

2.30 m

8.15 m

8.10 m

7.0 m

2.50 m

2.45 m

8.00 m

8.00 m

8.0 m

2.65 m

2.60 m

7.80 m

7.85 m

5.0

2.5 m

0.85 m

0.80 m

2.50 m

2.45 m

3.0 m

0.90 m

0.85 m

2.55 m

2.55 m

3.5 m

0.90 m

0.90 m

2.75 m

2.75 m

4.0 m

0.90 m

0.95 m

2.95 m

2.95 m

5.0 m

0.95 m

0.90 m

3.30 m

3.25 m

6.0 m

0.95 m

0.90 m

3.50 m

3.45 m

7.0 m

0.85 m

0.85 m

3.60 m

3.55 m

8.0 m

0.75 m

0.75 m

3.60 m

3.60 m

All values for ta = 30 °C
Luminous flux: 200 lm

1

 Maintainance factor = 0.8, photometric data available on request

2

 Distance between module and wall

3

 Distance between two modules

C0 / C90 / C180 / 270  

Summary of Contents for EM ready2apply SELFTEST 2 W SM

Page 1: ...pot illumination Emergency lighting with self test function BESA compatible mounting Properties Output power 1 5 W Very low stand by power loss Non maintained variants 1 or 3 h rated duration separate variants Simple connection of Lithium Iron Phosphate battery with plug in system White or black housing color options Back box in two different heights available for rear and side entry 5 years guara...

Page 2: ...e Mac Adams 3 Colour rendering index CRI 80 Lifetime up to 50 000 h EM ready2apply SELFTEST 2 W SM EM ready2apply 30 6 123 123 123 52 85 123 32 85 3 1 0 3 18 7 0 3 1 6 0 3 ø 4 1 0 3 ø 4 1 0 3 18 7 0 3 35 0 3 1 6 0 3 Ordering data Type2 Article number Colour Design Rated duration Number of cells Packaging carton Packaging pallet Weight per pc EM R2A ST NM 112 SM 89800790 White low 1 h 2 1 pc s 400 ...

Page 3: ... R2A ST NM 132 SMh 2 3 h 20 mA 10 mA 2 5 W 0 6 W 0 50c EM R2A ST NM 112 SM B 2 1 h 20 mA 10 mA 2 5 W 0 6 W 0 50c EM R2A ST NM 132 SM B 2 3 h 20 mA 10 mA 2 5 W 0 6 W 0 50c EM R2A ST NM 112 SMh B 1 h 20 mA 10 mA 2 5 W 0 6 W 0 50c EM R2A ST NM 132 SMh B 2 3 h 20 mA 10 mA 2 5 W 0 6 W 0 50c Emergency operation EM R2A ST NM 112 SM 2 1 h 126 mA 12 V 1 50 W EM R2A ST NM 132 SM 2 3 h 126 mA 12 V 1 50 W EM ...

Page 4: ... year design life up to 40 C ambient temperature 3 years guarantee Properties Certified quality manufacturer Charge efficiency 90 Low self discharge Simple connection with plug in system Protection and monitoring circuit built into battery sleeve Deep discharge protection Suitable for emergency lighting equipment as per IEC 60598 2 22 Lithium Iron Phosphate Battery pack 3 0 Ah Batteries ACCES SORI...

Page 5: ...sphere with corrosive gas Disconnect batteries before store or delivery Avoid storage of discharged batteries 3 Installation Wiring 3 1 Lens assembly Wear gloves when mounting the lens Take care of the mounting direction of the escape route lens Use screwdriver for replacing removing lens 1 2 Push lens clips with screwdriver via openings on both sides 3 Remove lens Expected lifetime Type ta 25 C 3...

Page 6: ... drill out Screw holes for BESA and general mounting are oval shape to allow adjust ment and are pre drilled to simplify the final installation 3 4 Wiring type and cross section Wiring Mains N L blue brown Rest orange orange Cable low smoke halogen free 8 1 mm wire preparation 0 5 2 5 mm2 The installation of the luminaire has to be done by a qualified person 4 Mechanical data 4 1 Housing propertie...

Page 7: ...e 290 mA 0 mA Discharge current at 3 2 V nominal 625 mA 1 Automatic recharge when battery voltage falls below 3 4 V Charger off 0 mA when battery voltage exceeds 3 6 V Note Battery protected against operation at excessive temperatures charging stopped when battery cell temperature 0 C or 60 C 5 4 Battery charge regime discharge EM R2A ST 2 W SM 1 3 h Type EM R2A ST 2 W SM Article no 89800790 93 89...

Page 8: ...atus indication System status is indicated by a bi colour LED The indication LED is integra ted in the bezel LED indiction Status Comment Permanent green System OK AC mode Fast flashing green 0 1 sec on 0 1 sec off Function test underway Slow flashing green 1 sec on 1 sec off Duration test underway Red LED on Load failure Open circuit Short circuit LED failure Slow flashing red 1 sec on 1 sec off ...

Page 9: ...ative intensity Iv Iv max Max spacing for 1 0 lux1 Height Centre to end2 Centre to centre3 Trans Axial Trans Axial 2 5 m 4 75 m 2 75 m 11 65 m 6 55 m 3 0 m 4 80 m 2 95 m 12 75 m 7 20 m 3 5 m 5 05 m 1 50 m 13 45 m 6 85 m 4 0 m 5 20 m 1 65 m 13 60 m 6 50 m 5 0 m 5 50 m 1 80 m 14 30 m 4 35 m 6 0 m 5 70 m 1 90 m 15 05 m 4 85 m 7 0 m 5 75 m 1 90 m 15 60 m 5 15 m 8 0 m 5 65 m 1 85 m 16 05 m 5 35 m All v...

Reviews: