www.tridonic.com
3
Subject to change without notice. Information provided without guarantee.
Data sheet 04/22-EM115-12
Emergency lighting units
EM LED Light Engines
Lens options
Anti panic, escape route, spot
A
CCES
-
SORIES
ANTI-PANIC (A)
ESCAPE ROUTE (E)
SPOT (S)
Ordering data
Type
Article number
Packaging, carton
Weight per pc.
Lens Kit R2A
89800557
1 pc(s).
0.012 kg
Specific technical data
Type
2
Number of
battery cells
Rated
duration
Mains current
(230 V, 50 Hz),
non-maintained
Mains power
(230 V, 50 Hz),
non-maintained
Typ. λ (at
230 V, 50 Hz,
charging)
Typ.
output
current
Typ.
forward
voltage
Output
power
Charging
Charger off
Charging
Charger off
Normal operation
EM R2A ST NM 112 SM
2
1 h
20 mA
10 mA
2.5 W
0.6 W
0.50c
–
–
–
EM R2A ST NM 132 SM
2
3 h
20 mA
10 mA
2.5 W
0.6 W
0.50c
–
–
–
EM R2A ST NM 112 SMh
�
1 h
20 mA
10 mA
2.5 W
0.6 W
0.50c
–
–
–
EM R2A ST NM 132 SMh
2
3 h
20 mA
10 mA
2.5 W
0.6 W
0.50c
–
–
–
EM R2A ST NM 112 SM-B
2
1 h
20 mA
10 mA
2.5 W
0.6 W
0.50c
–
–
–
EM R2A ST NM 132 SM-B
2
3 h
20 mA
10 mA
2.5 W
0.6 W
0.50c
–
–
–
EM R2A ST NM 112 SMh-B
�
1 h
20 mA
10 mA
2.5 W
0.6 W
0.50c
–
–
–
EM R2A ST NM 132 SMh-B
2
3 h
20 mA
10 mA
2.5 W
0.6 W
0.50c
–
–
–
Emergency operation
EM R2A ST NM 112 SM
2
1 h
–
–
–
–
–
126 mA
12 V
1.50 W
EM R2A ST NM 132 SM
2
3 h
–
–
–
–
–
126 mA
12 V
1.50 W
EM R2A ST NM 112 SMh
2
1 h
–
–
–
–
–
126 mA
12 V
1.50 W
EM R2A ST NM 132 SMh
2
3 h
–
–
–
–
–
126 mA
12 V
1.50 W
EM R2A ST NM 112 SM-B
2
1 h
–
–
–
–
–
126 mA
12 V
1.50 W
EM R2A ST NM 132 SM-B
2
3 h
–
–
–
–
–
126 mA
12 V
1.50 W
EM R2A ST NM 112 SMh-B
2
1 h
–
–
–
–
–
126 mA
12 V
1.50 W
EM R2A ST NM 132 SMh-B
2
3 h
–
–
–
–
–
126 mA
12 V
1.50 W
1
IK07 in case of fixing the front plate to the back box with a M3x10 self-tapping screw (not supplied). With clip fixing only IK03.
2
EM = Emergency
y