Emergency lighting units

EM converterLED

 

Product description

•  A green LED indicates that charging current is flowing into the 

battery

•  Plug connection

Status indication green LED

 

A

CCES

-

SORIES

 

Ordering data

Type

Article number

Packaging, 
bag

Packaging, 
carton

Weight 
per pc.

LED EM

 green, 1.0 m CON

89800269

25 pc(s).

200 pc(s).

0.015 kg

LED EM 

green, HO 1.0 m CON

89800271

25 pc(s).

200 pc(s).

0.015 kg

LED EM

 green, 0.6 m CON

89800472

25 pc(s).

200 pc(s).

0.009 kg

LED EM 

green, HO 0.6 m CON

89800473

25 pc(s).

200 pc(s).

0.009 kg

LED EM 

green, 0.3 m CON

89800270

25 pc(s).

200 pc(s).

0.005 kg

LED EM 

green, HO 0.3 m CON

89800272

25 pc(s).

200 pc(s).

0.005 kg

 

Product description

•  For connection to the emergency lighting unit

•  For checking the device function

•  Plug connection

Test switch EM3

 

A

CCES

-

SORIES

 

Ordering data

Type

Article number

Packaging, 
bag

Packaging, 
carton

Weight 
per pc.

Test switch EM 3

 

89899956

25 pc(s).

200 pc(s).

0.013 kg

EM converterLED BASIC NiCd 90 V

BASIC series

 

30

21

30

179

169.2

Duration
link  3 h

No 
duration
link  1 h

Note: LED Driver supplied with duration link in 3 hours position. Remove duration link for 
1 hour duration. Duration link must be set before battery and mains connection.

Technical data

Rated supply voltage

220 – 240 V

Mains frequency

50 / 60 Hz

Typ. λ (at 230 V, 50 Hz)

0.7

LED module forward voltage range

40 – 97 V

Output current

see chapter 5.2

Time to light

< 0.25 s from detection of emergency event

Overvoltage protection

320 V (for 48 h)

U-OUT

120 V

Battery charging time

24 h

1

Ambient temperature range ta

-5 ... + 55 °C

Max. casing temperature tc

75 °C

Mains voltage changeover threshold

according to EN 60598-2-22

Type of protection

IP20

Dimensions LxWxH

179 x 30 x 21 mm

Ordering data

Type

2

Article 

number

Rated 

duration

Number 

of cells

Packaging, 
carton

Packaging, 
pallet

Weight 
per pc.

EM converterLED BASIC 203 
NiCd 90V

 

89800561

1/3 h

3

10 pc(s).

1,600 pc(s).0.065 kg

EM converterLED BASIC 204 
NiCd 90V

89800562

1/3 h

4

10 pc(s).

1,600 pc(s).0.065 kg

Summary of Contents for BASIC Series

Page 1: ...ug duration link Compatible with all dimmable and non dimmable constant current LED Drivers see chapter 5 4 3 pole technology 2 pole LED module changeover and delayed power switching for the LED Driver Automatic shutdown of output if LED load is out of range Constant power output Maximum light output for all LED modules Electronic charge system Deep discharge protection Short circuit proof battery...

Page 2: ...ng function according to AS 2293 EM converterLED BASIC NiCd NiMH 90 V BASIC series 30 21 30 179 169 2 Duration link 3 h No duration link 1 h Note LED Driver supplied with duration link in 3 hours position Remove duration link for 1 hour duration Duration link must be set before battery and mains connection Ordering data Type1 Article number Rated duration Number of cells Packaging carton Packaging...

Page 3: ... 89800269 25 pc s 200 pc s 0 015 kg LED EM green HO 1 0 m CON 89800271 25 pc s 200 pc s 0 015 kg LED EM green 0 6 m CON 89800472 25 pc s 200 pc s 0 009 kg LED EM green HO 0 6 m CON 89800473 25 pc s 200 pc s 0 009 kg LED EM green 0 3 m CON 89800270 25 pc s 200 pc s 0 005 kg LED EM green HO 0 3 m CON 89800272 25 pc s 200 pc s 0 005 kg Product description For connection to the emergency lighting unit...

Page 4: ...life time 50 000 hours under rated conditions with a failure rate of less than 10 Average failure rate of 0 2 per 1000 operating hours Expected life time EM converterLED BASIC 203 NiCd NiMH 90V tc 65 C 70 C 75 C life time 100 000 h 93 000 h 66 000 h EM converterLED BASIC 204 NiCd NiMH 90V tc 65 C 70 C 75 C life time 100 000 h 79 000 h 55 000 h 3 Installation Wiring 3 1 Wiring diagram One or more L...

Page 5: ...LED Module Emergency Neutral P O Lout Lin N L L N Neutral Un Switched Line Test switch Indicator LED Switched Line in Switched Line out Control gear LED LED Control gear Battery Battery LED Module Emergency LED control gear max 150 W in operation EM ConverterLED BASIC EM converterLED BASIC with a standard LED Driver and series operation of LED modules Neutral P O Lout Lin N L L N Neutral Un Switch...

Page 6: ...eration LED Module Emergency LED Module Switched Line in Switched Line out EM ConverterLED BASIC Two or more LED modules are operated in emergency mode All LED modules are operated in mains mode EM converterLED BASIC with a standard LED Driver and parallel operation of LED modules Neutral P O Lout Lin N L L N Neutral Un Switched Line Test switch Indicator LED Control gear LED LED Control gear Batt...

Page 7: ...igh frequency content which should be considered for good EMC compliance LED leads should be separated from the mains connections and wiring for good EMC performance Maximum lead length on the LED terminals is 3 m For a good EMC performance keep the LED wiring as short as possible The secondary wires LED module should be routed in parallel to ensure good EMC performance Maximum lead length for the...

Page 8: ...switch Mounting hole 7 0 mm diameter Lead length 0 55 m Plug connection Battery leads Quantity 1 red and 1 black Length 1 3 m Wire type 0 5 mm2 solid conductor Insulation rating 90 C Battery end termination Push on 4 8 mm receptacle to suit battery spade fitted with insulating cover Module end termination 8 0 mm stripped insulation Two piece batteries are supplied with a 200 mm lead with 4 8 mm re...

Page 9: ...IC 204 NiCd NiMH 90V Article number 89800562 4 8 V battery voltage 850 960 mA battery discharge current tolerance VLED VLED 5 3 Typ LED current voltage characteristics The LED current in emergency mode is automatically adjusted by the EM converterLED module based on the total forward voltage of the LED modules con nected and the associated battery The start of the LED in emergency mode does not re...

Page 10: ...llowed output voltage of the associated LED Driver applied to the EM converterLED output is 450V voltage withstand between adja cent contact of the single switching relay of the EM converterLED The max allowed LED load of the associated LED Driver is 150 W in operation The load must be an LED module Check compatibility with short function tests duration of several seconds 6 Functions 6 1 Duration ...

Page 11: ...MH 4Ah 3A CON 89800441 stick 1 x 4 Accu NiMH 4Ah 4A CON 89800442 EM converterLED BASIC 1 3 h Type EM converterLED BASIC 203 NiCd NiMH 90V EM converterLED BASIC 204 NiCd NiMH 90V Article no 89800561 89800562 Cells 3 cells 4 cells Duration 1 h 3 h 1 h 3 h Battery charge time Initial charge 24 h Fast recharge 24 h Trickle charge continuously Charging current Initial charge 80 130 mA 170 220 mA 80 130...

Page 12: ...years design life 5 C to 55 C Max short term temperature reduced life time 70 C Max number discharge cycles 12 cycles per year plus 4 cycles during comissioning Max storage time 12 months 7 4 Accu NiMH 2 2 Ah International designation HRMU 23 43 Battery voltage cell 1 2 V Cell type Cs Case temperature range to ensure 4 years design life 5 C to 50 C Max short term temperature reduced life time 70 C...

Reviews: