l
Remove the socket head cap screws using a 5 mm Allen key
l
Remove the spring washer and the end cover
l
Discard the three O-rings (51.6 mm * 2.4 mm)
l
Draw the shuttle guide out using a 6 mm bolt
l
Clean the shuttle guide
l
Discard the O-ring (51.6 mm * 2.4 mm)
l
Remove the shuttle closer and o-ring (39.34 * 2.62) and discard it Replace it with new one
l
Remove the shuttle inlet and the shuttle closer
l
Discard the circlip and replace it with a new circlip
l
Reassemble the parts. Replace the discarded parts with new components
8.5.3.3 Servicing the exhaust valve
Figure 22. Exploded view of exhaust valve- Dryspell Plus models 45 and 60
INSTRUCTION MANUAL -
Dryspell Plus
Reference : Manual Version
34
Summary of Contents for DRYSPELL PLUS 10
Page 4: ......
Page 38: ...31 DRYSPELL PLUS 60 EXPLODED VIEW Drw No PD241 ...
Page 44: ...8 5 4 Dryspell Plus models 100 125 37 DRYSPELL PLUS 100 EXPLODED VIEW Drw No PD242 ...
Page 46: ...8 5 4 1 Changing the desiccant Figure 25 Changing desiccant Dryspell Plus model 100 39 ...
Page 52: ...8 5 5 Dryspell Plus models 200 250 45 DRYSPELL PLUS 200 EXPLODED VIEW Drw No PD244 ...
Page 60: ...DRYSPELL PLUS 375 EXPLODED VIEW Drw No PD247 53 ...
Page 70: ...INSTRUCTION MANUAL Dryspell Plus Reference Manual Version 64 Appendix Conversion tables ...