8.5.1.5 Changing the inlet tube
Figure 13. Views showing inlet air tube and associated components-
Dryspell Plus model 10
l
Using a screwdriver, disconnect the controller wire from the exhaust solenoid valve and prefilter solenoid valve
l
Remove the dome nuts and spring washers
l
Remove the top block
l
Discard the inlet air transfer tube
l
Discard the O-rings (10.6 mm * 1.83 mm)
l
Replace the inlet transfer tube with a new one
l
Fix the inlet tube on the bottom block with new O-rings
l
Replace the top block
l
Complete the reassembly with the spring washers and dome nuts
23