9
Model 2400 High-Pressure Filling System User Guide
Parts Included in the Model 2400 Filling System
▪
Model 2400 filling system
▪
Model 2400 filling system user manual
▪
2 Reservoirs with caps
▪
Foot switch
Operation
Operating the System
1.
Remove the Thumb Screws (Figure 6, A) and lift off the Heater Cover (Figure 6, B).
2.
Position the preheated reservoir into the Reservoir Guides (Figure 6, E).
3.
Push the Reservoir (Figure 6, D) into the Front Cap (Figure 6, I).
4.
Slide the End Cap (Figure 6, G) forward until it rests against the Reservoir.
5.
Secure the End Cap into position by tightening the Cylinder Nuts (Figure 6, G) until the Cup Washers
are flat.
6.
Replace the Heater Cover (Figure 6, B) and Thumb Screws (Figure 6, A).
7.
Ensure that the Hydraulic Switch (Figure 6, F) in is the dispense position.
8.
Place a syringe onto the Nozzle to be filled (Figure 7).
9.
Depress the Footswitch.
10.
After the syringe is filled, the system will automatically stop and wait to be to be reloaded.
11.
Continue these instructions until the Reservoir is emptied.