background image

3

Contents

For the User

For the Installer

Important Safety Information

2

Description of the Hob

3

Operation

4

Maintenance and Cleaning

4

Something Not Working?

5

Service and Spare Parts

6

Guarantee Conditions

6

Engineers technical data

9

Installation

10

Building In

11

Electrical connections

12

Wiring Diagram

13

Fault Finding

13

Commissioning

15

Conversion from Natural Gas to LPG

15

1.

Hob Top

2.

Auxiliary Burner

3.

Semi-rapid Burners

4.

Ultra-rapid Double-crown Burner

5.

Rapid Burner

6.

Ignition pushbutton

7-11. Control knobs

3

2

4

5

6 7

8 9

3

10 11

Description of the Hob

1

Summary of Contents for TBG 750

Page 1: ...GAS HOB MODEL TBG 750 Please read this instruction booklet before using the appliance ...

Page 2: ...b is intended for domestic cooking only It is not designed for commercial or industrial purposes l When in use a gas cooking appliance will produce heat and moisture in the room in which it has been installed Ensure there is a continuous air supply keeping air vents in good condition or installing a cooker hood with a venting hose l When using the hob for a long period of time the ventilation shou...

Page 3: ...ts 6 Guarantee Conditions 6 Engineers technical data 9 Installation 10 Building In 11 Electrical connections 12 Wiring Diagram 13 Fault Finding 13 Commissioning 15 Conversion from Natural Gas to LPG 15 1 Hob Top 2 AuxiliaryBurner 3 Semi rapidBurners 4 Ultra rapidDouble crownBurner 5 RapidBurner 6 Ignitionpushbutton 7 11 Controlknobs 3 2 4 5 6 7 8 9 3 10 1 1 Description of the Hob 1 ...

Page 4: ...hown in the diagram Take care when frying food in hot oil or fat as the overheated splashes could easily ignite If the control knobs become difficult to turn please contact your local Service Force Centre Maintenance and Cleaning If you use a saucepan which is smaller than the recommended size the flame will spread beyond the bottom of the vessel causing the handle to overheat As soon as a liquid ...

Page 5: ...hecks before contacting your local Service Force Centre IMPORTANT If you call out an engineer to a fault listed below or to repair a fault caused by incorrect use or installation a charge will be made even if the appliance is under guarantee SYMPTOM n There is no spark when lighting the gas n The gas ring burns unevenly SOLUTION u Check that the unit is plugged in and the electrical supply is swit...

Page 6: ...wing qualifications The guarantee starts from the date you first purchased your product The guarantee is for the same period and to the same extent for labour and parts as exist in the new country of use for this brand or range of products This guarantee relates to you and cannot be transferred to another user Your new home is within the European Community EC or European Free Trade Area The produc...

Page 7: ...M38 Roman Ridge Ind Roman Ridge Road Sheffield S9 1GB NORTH WEST BIRKENHEAD 1 Kelvin Park M11 Dock Road Birkenhead L41 1LT CARLISLE Unit 8 M10 South John Street Carlisle CA2 5AJ ISLE OF MAN South Quay Ind M64 Estate Douglas Isle of Man LIVERPOOL Unit 1 M15 Honeys Green Precinct Honeys Green Lane Liverpool L12 9JH MANCHESTER Unit 30 Oakhill Trading M09 Estate Devonshire Road Worsley Manchester M28 ...

Page 8: ...EW ENFIELD 284 Alma Road M49 Enfield London EN3 7BB GRAVESEND Unit B4 M57 Imperial Business Estate Gravesend Kent DA11 0DL HARPENDEN Unit 4 M46 Riverside Estate Coldharbour Lane Harpenden AL5 4UN LETCHWORTH 16 17 Woodsite Ind M50 Est Works Road Letchworth Herts SG6 1LA LONDON 2 4 Royal Lane M76 Yiewsley West Drayton Middlesex UB7 8DL MAIDENHEAD Reform Road M60 Maidenhead Berkshire SL6 8BY MOLESEY ...

Page 9: ...p Fixed Rear Left Burner semi rapid Heat Input 2 0 kW 6824 BTU HR Front Left Burner auxiliary Heat Input 1 0 kW 3412 BTU HR Burner Dia Tap By pass 1 100 mm Auxiliary 28 Semi rapid 32 Rapid 40 Ultra rapid 56 Aerationadjustmentnone NATURAL GAS 20 mbar TYPE OF GAS Characteristics LPG GAS 28 30 37 mbar 1 100 mm 1 100 mm VALUE 49 92 MJ Kg VALUE 37 78 MJ m 3 Ws 50 7 MJ m 3 Rear Right Burner semi rapid H...

Page 10: ...ir vent requirements Location The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathroom or shower room Before making the cut out in the worktop ensure that the edges of the hob that are to be near either a side or rear wall have a minimum distance of 55 mm between the edge of the hob and the wall The minimum distance combustible material can be fitted above the ...

Page 11: ...ow easy access if technical assistance is needed The space behind the kitchen unit b can be used for connections Rectangular cut out size for hob A End of shaft with nut B Washer C Elbow It is important to install the elbow correctly with the shoulder on the end of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas FO 0814 Gas Connection C...

Page 12: ...roved BS 1362 fuse must be used Should the plug need to be replaced for any reason the wires in the mains lead are coloured in accordance with the following code Green and Yellow Earth Blue Neutral Brown Live Connect the green and yellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow Connect the blue neutral wire to the ter...

Page 13: ...ss than infinity there is a fault NOTE Should it be found that the fuse has failed but no fault is indicated a detailed continuity check i e by disconnecting and checking each component is required to trace the faulty component It is possible that a fault could occur as a result of local burning arcing but no fault could be found under test However a detailed visual inspection should reveal eviden...

Page 14: ...Light burner manually Check gas supply at burner Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 4 on the ignitor unit Check for breaks in the insula...

Page 15: ...reading should be nominally 20mbar and must be between 17 mbar and 25mbar Turn off the burner supplies F F Conversion from Natural Gas to LPG It is important to note that this model is designed for use with natural gas but can be converted for use with butane or propane gas providing the correct injectors are fitted The gas rate is adjusted to suit Method Ensure that the gas taps are in the OFF po...

Page 16: ...Customer Care Departement Tricity Bendix 55 77 High Street Slough Berkshire SL1 1DZ Tel 08705 950950 Electrolux Household Appliances Limited 2000 35674 6901 05 00 ...