9
BURNER
RAPID
SEMI-RAPID AUXILIARY ULTRA-RAPID
(large)
(medium) (small) (double-crown)
POSITION
MAX
MIN
MAX
MIN
MAX
MIN
MAX
MIN
NOMINAL THERMAL
POWER kW
3.0
0.65
2.0
0.45
1.0
0.33
3.5
1.2
NOMINAL FLOW
RATE m
3
/h 0.286
0.062
0.190
0.043
0.095
0.031
0.333 0.114
NOZZLE REFERENCE
119
Adjust.
9 6
Adjust.
7 0
Adjust.
136 Adjust.
NOMINAL THERMAL
POWER kW
2.8
0.65
2.0
0.45
1.0
0.33
3.5
1.2
NOMINAL FLOW
RATE g/h
202
4 7
144
3 2
7 2
2 4
252
8 6
NOZZLE REFERENCE
8 6
4 0
7 1
3 2
5 0
2 8
9 3
5 6
OVERALL DIMENSIONS
Width:
680 mm.
Depth:
510 mm.
Height:
72 mm.
CUT OUT DIMENSIONS
Width:
560 mm.
Depth:
480 mm.
Thickness: 30 mm.
Ignition HT Spark
Spark Generator
Ispra Control's BF 50066 - 240V 0.6 YA T 120
Spark Gap
Fixed
Rear Left Burner (semi-rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Left Burner (auxiliary)
Heat Input 1.0 kW (3412 BTU/HR)
Burner
Dia. Tap By-pass
1/100 mm
Auxiliary
28
Semi-rapid32
Rapid40
Ultra-rapid56
Aeration adjustment none
NATURAL
GAS
20
mbar
TYPE
OF
GAS
Characteristics
LPG GAS
28-30/37
mbar
1/100 mm
1/100 mm
VALUE
=
49.92
MJ/Kg
VALUE
=
37.78
MJ/m
3
Ws
- 50.7
MJ/
m
3
Rear Right Burner (semi-rapid)
Heat Input 2.0 kW (6824 BTU/HR)
Front Right Burner (rapid)
Heat Input 3.0 kW (10236 BTU/HR)
SUPPLY CONNECTIONS
Gas:
RC 1/2 inch (1/2 inch male) Rear right hand corner
Electric:
230-240V 50Hz supply, 3 core flexible cable with non
rewireable plug fitted with a 3 amp cartridge fuse.
Central Burner (Ultra-rapid Double-crown)
Heat Input 3.5 kW (11942 BTU/HR)
Instructions for the Installer
Engineers technical data
APPLIANCE CLASS : 3
APPLIANCE
CATEGORY: II2H3+
APPLIANCE
GAS SUPPLY: Natural gas G20 / 20mbar