33
Electrical connection
Cookers are designed to operate exclusively on 50Hz
AC power -- (refer to the label sticked on the cord).
Check that:
•
the mains supply is correct,
•
the mains cable is not damaged,
•
the mains cable is the correct specification,
•
the mains supply is provided with a means of
isolation comprising of a double pole switch with a
minimum contact opening distance of 3 mm, and
ensuring that the earth connection is not broken.
Installation and maintenance must be done by a
qualified professional in accordance with the
regulatory texts and current IEE regulations.
We cannot be held responsible for accidents or
incidents caused by incorrect or defective
earthing.
Mains cable
This cooker is supplied with a special heat resistant
mains cable (type H07 RN--F / 2,00 m), which MUST
NOT be removed. If this cable becomes damaged, or
needs to be replaced for any reason, then only the
cable with
Part Number 337225201/9
must be used,
which can be obtained from your local Service Force
Centre.
The manufacturer will not be responsible for any
damage or injury if this warning is ignored.
Fuse rating
30 Amps