The microelectronics integrated in the FP1 B permanently monitors the status. In the
event of irregularities, an addressed error message is displayed on the LCD. The red
LED flashes every 5 seconds and also signals an error optically.
LCD
Name Description
Remedy
Error
E1
Cartridge Error;
Cartridge not
recognized or
corrently not
mounted
Place a new cartridge on FP1
B (see chapter 7.2).
No confirmation of the error
necessary; it is automatically
cleared after the remedial
action.
Error
E1
Cartridge
(Symbol) empty
Place a new cartridge on FP1
B (see chapter 7.2).
No confirmation of the error
necessary; it is automatically
cleared after the remedial
action.
Error
E2
Overload; the
back pressure
at the lubricati-
on point is too
high.
Check the lubrication point
and eliminate the cause of the
fault.
Switch FP1 B off (OFF) and
on (ON) again.
Error
E3
Battery empty
Switch FP1 B off (OFF).
Replace the battery together
with the cartridge (see chapter
Switch FP1 B on (ON).
E1
E2
E3
E1
6.4
Error codes
The FIL-Menu can only be reached from the ON mode (FP1 B switched on). When
you enter the FIL-Menu, you will return to the ON mode, even if you cancel FIL prema-
turely with CLR.