Technical Data

Type

IFM 120

IFM 130

IFM 135

Order No.

940 320-001

940 321-001

940 322-001

Frequency range

Input 1 - UHF (1)

MHz

470...862  

470...862

470...862

Input 2 - VHF III  

MHz

174...230  

174...230

174...230

Input 3 - VHF I

MHz

-

47...68

-

- UHF (2)

MHz

-

-

470...862

Input 4 - FM

MHz

47...68 and

-

47...68 and

- VHF I

MHz

87,5...108

87,5...108

87,5...108

option: input 1 and input 2

combined with jumper

MHz

470...862 and

470...862 and

470...862 and

174...230

174...230

174...230

Gain *

Input 1 - UHF (1)

dB 

22

31

35

Input 2 - VHF III 

dB

20

30

34

Input 3 - VHF I

dB

-

30

-

- UHF (2)

dB

-

-

35

Input 4 - FM / VHF I

dB

20

30

34

Level controller

at all inputs

dB 

0...-20

0...-20

0...-20

Noise figure * 

Input 1 - UHF (1)

dB 

4

4

7

Input 2 - VHF III 

dB

4

4

5

Input 3 - VHF I

dB

-

4

-

- UHF (2)

dB

-

-

7

Input 4 - FM / VHF I

dB

4

4

5

Output level, IMR = 60 dB *

IMR 3 acc. EN 50083-5 

dBµV 

113

115

121

IMR 2 acc. EN 50083-3 

dBµV 

102

105 

110

Power supply

Supply voltage (50 - 60 Hz) 

V~

230 ±10%

230 ±10%

230 ±10%

Power consumption

W

3,5

6

7,5

Ambient conditions acc. EN 60065

Operating temperatur range 

°C 

–25 … +55

–25 … +55

–25 … +55

Degree of protection 

II, isolated guard

II, isolated guard

II, isolated guard

Protection class 

IP 20

IP 20

IP 20

MTBF (Belcore @ 25°C)

h

300.000

300.000

300.000

Housing

Weight 

kg 

ca. 0.68

ca. 0.68

ca. 0.68

Dimensions W x H x D 

mm 

150 x 80 x 50

150 x 80 x 50

150 x 80 x 50

HF connections 75 

O

F connectors

F connectors

F connectors

Screening

acc. EN 50083-2

class A

class A

class A

*

Level controller 0 dB

TRIAX A/S

Bjørnkærvej 3

DK-8783 Hornsyld

Phone: +45 76 822 200

Fax: +45 75 687 966

www.triax.com

Summary of Contents for IFM 120

Page 1: ...Model Item no IFM 120 339120 IFM 120 339130 IFM 120 339135 Version EN triax com Operating Instructions Terrestrial Multiband amplifier ...

Page 2: ...ed on wall Installed in a cabinet only in strict conformance to the permissible ambient operating temperature measured in the air stream underneath the amplifier 3 3 Wall mounting Fixed to brackets by appropriately sized screws dia max 4 8 mm Fixings 158 mm apart When this product has reached the end of its useful life it is to be turned in for proper disposal as electronic refuse in compliance wi...

Page 3: ...eleasing the catch on the left hand side b For adjustments now the level adjusters and the jumper on the circuit board are accessible Fig 1 Housing 2 Adjuster elements Fig 2 Adjuster elements Level adjuster 0 20 dB at all inputs Position of the jumper 3 Close the housing lid Put the housing lid on the housing and press all the way round The sheet steel segments will now be pressed against the inne...

Page 4: ...t 2 VHF III dB 4 4 5 Input 3 VHF I dB 4 UHF 2 dB 7 Input 4 FM VHF I dB 4 4 5 Output level IMR 60 dB IMR 3 acc EN 50083 5 dBµV 113 115 121 IMR 2 acc EN 50083 3 dBµV 102 105 110 Power supply Supply voltage 50 60 Hz V 230 10 230 10 230 10 Power consumption W 3 5 6 7 5 Ambient conditions acc EN 60065 Operating temperatur range C 25 55 25 55 25 55 Degree of protection II isolated guard II isolated guar...

Page 5: ... für DVB T als auch für analoge Antennensignale geeignet 3 3 VHFIII und UHF können Sie wahlweise getrennt betreiben oder die beiden Ausgänge zusammenlegen durch Umstecken des Jumpers z B bei Verwendung von Kombi Antennen 3 3 Zuschaltbare Fernspeisung von 5 V zu den Eingängen UHF oder VHF III z B zur Stromversorgung aktiver DVB T Antennen 3 3 Pegelsteller 0 20 dB an jedem Eingang 3 3 Niedriger Ener...

Page 6: ...rf keinem Tropf oder Spritzwasser ausgesetzt werden Sicherheitsanforderungen Montage 3 3 Montageort und Einbaulage so wählen daß die Konvektionskühlung des Verstärkers nicht behindert wird Montage waagrecht senkrechte Ausrichtung der Kühlrippen siehe Abb 1 frei an der Wand Einbau in einen Schrank nur bei Beachtung der zulässigen Betriebs Umgebungs temperatur gemessen am Luftstrom unter dem Verstär...

Page 7: ...Deckel anhand der kleinen Halterung links b nach vorne abgenommen Nun sind Pegelsteller und Jumper auf der Leiterplatte für Einstellungen zugänglich Abb 1 Gehäuse 2 Einstellungen vornehmen Abb 2 Einstellelemente Pegelsteller 0 20 dB an jedem Eingang Stellung des Jumpers 3 Gehäusedeckel schließen Den Gehäusedeckel passend auf das Gehäuse aufsetzen und ringsum andrücken so dass die Blechlamellen im ...

Page 8: ...20 30 34 Eingang 3 VHF I dB 30 UHF 2 dB 35 Eingang 4 FM VHF I dB 20 30 34 Pegelsteller an allen Eingängen dB 0 20 0 20 0 20 Rauschmaß Eingang 1 UHF 1 dB 4 4 7 Eingang 2 VHF III dB 4 4 5 Eingang 3 VHF I dB 4 UHF 2 dB 7 Eingang 4 FM VHF I dB 4 4 5 Ausgangspegel IMA 60 dB IMA 3 gem EN 50083 5 dBµV 113 115 121 IMA 2 gem EN 50083 5 dBµV 102 105 110 Elektrische Anschlusswerte Versorgungsspannung 50 60 H...

Reviews: