Safety Requirements
CAUTION: Observe the safety requirements
of EN 50083 -1
3
3
Equipotential bonding
The complete system must be provided with
equipotential bonding by means of a
mechanically stable protective conductor with
a minimum cross-section of 4 mm
2
. There is a
connection point at the earthing screw at the
right wall bracket.
NOTE:
The unit must not be exposed to
dripping or splashing water.
Installation
3
3
Choose a location and orientation that will not
impair the convection cooling of the amplifier:
•
Horizontal (cooling fins aligned vertically)
•
Uncovered on wall
•
Installed in a cabinet only in strict
conformance to the permissible ambient
operating temperature (measured in the air
stream underneath the amplifier)
3
3
Wall mounting
•
Fixed to brackets by appropriately sized
screws (dia. max. 4.8 mm)
•
Fixings 158 mm apart