- 23 -
- 23 -
• Press the
button.
—> The “Selecting the input data stream” – “
INPUT
” menu
is activated when the input signal source “
Tuner A
”
without a CA module installed and “
Tuner B
” are pro-
grammed (page 19).
—> Programming the input signal source “
Tuner A
” with
a CA module installed the “Setting the operating volt-
age for the CA module” – “
CA Supply
” menu is
activated (page 31).
• Use the
buttons to select further input signal sources
(“
Tuner B
” / “
ASI
”) and program them.
• Press the
button.
—> The “Allocating the IP addresses” – “
IP-OUT 1
” menu
is activated.
Allocating the IP addresses
In this menu up to 16 services that are contained in the data
streams of the input source signals (“
Tuner A
”, “
Tuner B
”,
“
ASI
”) can be accessed. The services detected receive an IP
address automatically.
In the following sub-menus you can set specific parameters
for each service.
• Press the
buttons to select the IP outputs to be set
(“
IP-OUT 1
” … “
IP-OUT 16
”).
—> In the second line of the display the service is indi-
cated allocated to the IP output (e.g. ”
Das Erste
”).
• Press the
▶
button.
—> The “Switching the IP address off or on, selecting the
transmission protocol, setting the port number” –
“
MODE / PORT
” menu is activated.
IP-OUT 1
…
IP-OUT 16
IP 1
on UDP
MODE / PORT
1234
Å
Ï
/
Å
Bx 4
Das Erste
IP-OUT 1
=>
on / off
UDP / RTP,
0 … 65535
copy
IP 1
on
UDP
MODE / PORT
1234
Å
Ï
/
on / off
UDP / RTP,
0 … 65535