WARNING
!
Indicates a potentially hazardous situation
which, if ignored, can result in serious injury or
substantial property damage.
NOTICE
Indicates special instructions on installation, operation
or maintenance, which are important to equipment
but not related to personal injury hazards.
WARNING
!
For your safety, turn off electrical power supply
at service panel and allow unit to cool before
proceeding to avoid possible electrical shock and
scald hazard. Failure to do so can cause severe
personal injury or death.
NOTICE
Upon completion of the conversion from Natural Gas to
Propane, affix the new rating label included in the kit to
the unit adjacent to the existing rating label. DO NOT
affix the new label over the existing rating label. Add
propane conversion labelling to the gas valve.
WARNING
!
Failure to follow instructions below can result in
severe personal injury or damage if ignored.
• Instructions are for a qualified installer/
service technician only.
• Read all instructions before proceeding.
• Follow instructions in proper order.
NOTICE
These instructions cover NG to LP conversion for Instinct
boilers only. Each kit is supplied with one venturi suitable
for use with that particular boiler model.
Kit Part Number
• INSRKIT08 (Solo 110)
• INSRKIT10 (Solo/Combi 155)
• INSRKIT12 (Solo/Combi 199)
Kit Includes
• Rating Label
• Conversion Label
• (1) Propane Gas Venturi
• Acoustic Foam (required for 110 and 155 models ONLY)
Recommended Tools
• Adjustable Wrench / 10 mm Socket & Ratchet
• Phillips Head Screwdriver
• Flat Head Screwdriver
• Calibrated Combustion Analyzer
Instinct Solo/Combi
Natural Gas to Propane Conversion Instructions
227797 A02
Revision Date: 05/2021
2019-18 Instinct NG to LP Conversion
NOTICE
When converting the appliance from Natural Gas to Propane ensure that the conversion is completed before fully installing
the air inlet piping.