background image

CHALLENGER

DHW Flow Restrictor Instructions

1

Kit Part Number: CCRKIT39

Kit Includes:

- Red 3.1 GPM Flow Restrictor (CC 125)
- Blue 2.6 GPM Flow Restrictor (CC 105)
- White 2.1 GPM Flow Restrictor (CC 85)
- C Clip

Recommended Tools:

-

C Clip Pliers

-

Adjustable Wrenches

For  your  safety,  turn  off  electrical  power
supply  at  service  panel  and  allow  appliance
to  cool  before  proceeding.  Failure  to  do  so
can cause severe personal injury or death.

Failure  to  follow  instructions  below  can
result in severe personal injury or damage if
ignored.

Instructions  are  for  a  qualified  installer/
service technician.

Read all instructions before proceeding.

•  Follow instructions in proper order

.

WARNING

WARNING

Indicates  a  potentially  hazardous  situation
which  if  ignored,  can  result  in  serious
injury or substantial property damage.

Indicates  special  instructions  on  installa-
tion,  operation  or  maintenance,  which  are
important  to  equipment  but  not  related  to
personal injury hazards.

WARNING

NOTICE

The installation of a domestic hot water (DHW) flow restrictor is recommended to ensure a
constant supply of hot water especially to tubs where the flow can easily exceed the appliance
capabilities. The DHW flow restrictor must be installed in the DHW inlet adapter, refer to
Fig. 1, page 2 for proper color (size) of restrictor for any given model and proper installation
using the c-clip.

NOTICE