Trianco Electronic Programmer -
2 Channel Version
Specification
Power Supply
:
220/240Vac, 50/60 Hz
Switching Action
: 2 x2 SPDT, Type 1b
Switch Rating
: 220/240Vac, 50/60 Hz, 3(1)A
Timing Accuracy
: ± 1min/month
Power Reserve
: 14 days
Enclosure Rating
: IP30
Maximum Ambient Temp : 45°C
Designed to meet BS3955 and BS E60730-2-7
Overall Dimensions
: Width: 86.5mm
Height: 88mm
Depth: 35mm
Control Pollution Situation: Normal
Initial Power-Up
This unit may be in its ‘Sleep Mode’. After the unit is
installed press the four buttons: ‘SELECT / ADVANCE
/ - / +’ all at the same time to ‘Wake up’ the unit before
programming.
General
The programmer has been pre-installed in the boiler dur-
ing manufacture. During installation the programmer will
have been correctly configured for the boiler and been
set up as a 24 hour unit, repeating its programme each
day.
However should the consumer prefer to have 5 day/2 day
operation, the unit can be re-configured on site by altering
the position of a DIL switch on the rear of the programmer.
Caution:
This should only be undertaken by a competent
person. If in any doubt, consult a qualified electrician.
24 HR
PUMP
5/2 DA
Y
GRA
VITY
Rear view of unit
Programmer with programming cover
Boiler Type: Eurostar Combi 65
Switch Legend
Factory Setting
24 Hour - 5/2 Day
24 Hour
Pump Gravity
G
Location and setting of DIL Switches
The DIL switches are located on the bottom right hand side
of the rear of the unit.
Factory Settings
Changes to factory settings
24 Hour or 5/2 day operation
This can be changed to suit the needs of the end user.
Pump or Gravity
This should be left at the setting applicable to the boiler
type (see above for details).
Setting the time Danfoss OEM5
1.
Remove white protective cover from base of programmer.
2. Activate programmer, pressing four buttons
(select, advance and +Plus -Minus) together.
3.
12.00 will appear in window either-12.00a.m. or 12.00
p.m.
4. Press programmer button.
5. Press +Plus or Minus buttons to adjust time to AM or
PM.
6. Press programmer button.
7. To set on/off times refer to Setting event times
Setting event times
Step A
Press PROG to advance to the next step. The display will
be as in figure 5.
Step B
Press and release the + or - buttons to change event 1
ON time in increments of 1 minute.
Note:
If buttons are held down, the time will change in
increments of 10 minutes.
Step C
Press PROG again to select event 1 OFF time. The dis-
play will be as in figure 10.
Repeats Steps A, B and C above for event 2 ON/OFF
times and again for event 3 ON/OFF times before pressing
PROG again to return to RUN mode.
Having finished programming, replace the programming
button cover.
14
Summary of Contents for Combi 50 ECO
Page 10: ...7 Fig 2...
Page 14: ...11 Fig 4 EUROSTAR COMBI SCHEMATIC LAYOUT Fig 5 SEALED SYSTEM PIPING SCHEMATIC DIAGRAM...
Page 20: ...17 Fig 11 SINGLE PIPE OIL SUPPLY HEAD H METRES...
Page 21: ...18 Fig 12 TWO PIPE OIL SUPPLY...
Page 22: ...19 Fig 13 DE AERATED OIL SUPPLY INSTALLATION...
Page 32: ...29 Fig 20 2273 VERTICAL B F KIT 2273 Vertical Balanced Flue Kit 600mm 24 3000mm MAX 118...