Problem: The Tool Bit is diving and the SEVERMASTER
TM
is stalling
The tool bit is dull, chipped, etc.
The tool holder adjustment slide is too loose.
The tool bit is over-extended
Problem: The pipe or tube is slipping in the collet
The clamping pressure is not tight enough.
Scale and/or other foreign material is present on the pipe or tube.
Weld seams, swelling, or bumps are preventing full contact of the collet.
Dull tool bits are causing extra force in the axial and/or radial direction.
Problem: There's a Loss of Air Power
The air supply pressure is too low.
The air filter is plugged.
The air line size is insufficient.
The air line is too long.
Problem: The Tool Bit Will Not Reach the Work
Incorrect tool blocks are installed for the size of the pipe or tube being
worked on.
Incorrect tool bit is installed.
Problem: The Air Motor Will Not Start
The air power supply is shut off.
The air motor is damaged and will not run free.
The air motor needs lubrication.
Add lubrication and do not run the air motor for a few minutes, then try
running the motor.
Tap on the side of the air motor casing lightly with a piece of wood or with a
soft rubber mallet just in case the vanes may be sticking.
Sand or other foreign material may be in the vanes of the air motor.
Summary of Contents for SEVERMASTER 576AC
Page 1: ...Operation Manual 92 1924 Orig 201016 Model 576AC SEVERMASTER ...
Page 19: ...Model 576AC SEVERMASTER 92 1924 Orig 201016 17 Collets Continued ...
Page 20: ...TRI TOOL INC 92 1924 Orig 201016 18 9 TOOL BITS ...
Page 28: ...TRI TOOL INC 92 1924 Orig 201016 26 This Page Intentionally Left Blank ...
Page 30: ......
Page 32: ......
Page 38: ...TRI TOOL INC 92 1924 Orig 201016 36 This Page Intentionally Left Blank ...
Page 39: ......