12.
Push the ‘START’ button to start the unit. The charge pump does not
circulate oil if rotated in the reverse direction and overheats in about 10
seconds of continuous reverse running. The motor has a run direction
arrow.
View the motor fan through a hole in the top of the housing.
View the pump to motor coupling through the adapter port.
13.
If necessary, reverse the two power leads to the starter to change the
direction of a three-phase motor.
14.
Proceed with the operation.
15.
Push the ‘STOP” or “E-stop’ button to stop the 756RVC2.
WARNING
WARNING: Do not drive the hydraulic pump backward or counter-clockwise.
Figure 5: Operator’s Pendant