CAUTION:

  These  models  are  designed,  built,  and  sold  for  commercial  use.  If  these 

models  are  positioned  so  the  general  public  can  use  the  equipment,  make  sure  that 
cautions,  warnings,  and  operating  instructions  are  clearly  posted  near  each  unit  so  that 
anyone  using  the  equipment  will  use  it  correctly  and  not  injure  themselves  or  harm  the 
equipment. 

 

 

 

WARNING:

  Improper  installation,  adjustment,  alteration,  service  or  maintenance  can 

cause property damage, injury or death. Read the installation, operating and maintenance 
instructions thoroughly before installing or servicing this equipment. 

 

 

 

WARNING:

  For  your  safety  do  not  store  or  use  gasoline  or  other  flammable  vapors  and 

liquids  in  the  vicinity  of  this  or  any  other  appliance.  Keep  the  area  free  and  clear  of 
combustibles. (See ANZI Z83. 14B, 1991). 

 

 

 

NOTICE:

 Instructions to be followed if anyone smells gas should be posted in a prominent 

place. These may be obtained from the gas supplier. 

 

 

GAS PRESSURE 

The  appliance  and  it’s  individual  shutoff  valve  (to  be  supplied  by  user)  must  be  disconnected  from  the  gas 
supply piping system during any pressure testing of that system at test pressures in excess of ½ psi (3.45 kPa). 

The appliance must be isolated from the gas supply piping system by closing it’s individual manual shut-off valve 
during  any  pressure  testing  of  the  gas  supply  piping  system  at  test  pressures  equal  to  or  less  than  ½  psi  
(3.45 kPa).

 

 

WARNING:

 A factory authorized agent should handle all maintenance and repair. Before 

doing any maintenance or repair, contact Tri-Star. 

 

 

Congratulations  on  your  purchase  of  Tri-Star  commercial  cooking  or  refrigeration  equipment.  Tri-Star 
Manufacturing  takes  pride  in  the  design  and  quality  of  our  products.  When  used  as  intended  and  with  proper 
care  and  maintenance,  you  will  experience  years  of  reliable  operation  from  this  equipment.  To  ensure  best 
results, it is important that you read and follow the instructions in this manual carefully. 
 

TABLE OF CONTENTS 

 

 

 

ITEM 

PAGE 

ITEM 

PAGE 

Safety Precautions ............................................ 3 

Cleaning/Maintenance ............................................ 8 

General Installation Instructions ........................ 4 

Service/Repair ........................................................ 9 

Specifications & Dimensions ............................. 4 

Troubleshooting Guide ........................................... 9 

Conversion ........................................................ 7 

Replacement Parts Lists & Exploded Views ......... 11 

Lighting Instructions .......................................... 7 

Warranty ............................................................... 19 

Operation Instructions ....................................... 7 

 

 

LOCATION OF DATA PLATE 

The data plate is located on the rear panel.

 

Summary of Contents for TSGCB-18i

Page 1: ... WARNING Improper installation operation service or maintenance can cause property damage injury or death Read and understand these instructions thoroughly before positioning installing maintaining or servicing this equipment WARNING Instructions must be posted in a prominent location All safety precautions must be taken in the event the user smells gas Safety information can be obtained from your...

Page 2: ...s supply piping system during any pressure testing of that system at test pressures in excess of psi 3 45 kPa The appliance must be isolated from the gas supply piping system by closing it s individual manual shut off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than psi 3 45 kPa WARNING A factory authorized agent should handle all maintenanc...

Page 3: ...l result in serious injury or death WARNING This symbol refers to a potential hazard or unsafe practice which could result in serious injury or death CAUTION This symbol refers to a potential hazard or unsafe practice which may result in minor or moderate injury or product or property damage NOTICE This symbol refers to information that needs special attention or must be fully understood even thou...

Page 4: ... gas line is disconnected Unit must have adequate clearances for servicing Sides 0 Rear 0 Floor 4 European Community Installation Instructions THIS APPLIANCE MUST BE FITTED BY A COMPETENT PERSON IN THE UK CORGI REGISTERED INSTALLERS INCLUDING THE REGIONS OF BRITISH GAS UNDERTAKE TO WORK TO SAFE AND SATISFACTORY STANDARDS THIS APPLIANCE MUST BE INSTALLED IN ACCORDANCE WITH THE GAS SAFETY INSTALLATI...

Page 5: ...emove the knobs and front panel 2 Remove the orifice fittings from the valve Change the orifices to the size recommended for propane L P 3 Replace the orifice fittings into the valve 4 Remove cap invert the insert and replace cap NOTE Marking on insert 5 Continue with the installation LIGHTING INSTRUCTIONS GCB and GCRB Broilers are furnished with either a pilot safety valve or a standing pilot not...

Page 6: ...Turn off the manual shut off valve and wait 5 minutes to clear the gas 2 Turn all knobs to the OFF position 3 Turn the manual shut off valve on 4 Hold an ignition source match at the pilot When the flame is established remove the ignition source 5 Turn the burner knobs to HI If the burner does not ignite promptly open the pilot valve more If the pilot flame appears larger than necessary turn it do...

Page 7: ...currents within a room It is also necessary that sufficient air should be allowed to enter the room to compensate for the amount of air removed by any ventilating system Otherwise a subnormal atmospheric pressure will occur which will effect operation and cause undesirable working conditions A properly designed and installed hood will act as the heart of the ventilating system for the room or area...

Page 8: ...ricting the airflow by covering the grid grates may cause them to warp It will also cause damage to the valves the knobs and the front panel decal C Place grates on broiler with grid bars horizontal facing down D Turn control knobs to HI for approximately 45minutes E Turn off the broiler and allow it to cool for 20Minutes F Clean top and bottom surfaces of grate with a wire brush to remove animal ...

Page 9: ...djusted by the installer unless the installer is an authorized service agent TROUBLE SHOOTING GUIDE PROBLEM POSSIBLE CAUSE Heat does not come on when valve is turned on Pilot burner not lit Gas valve is bad Pilot burner will not light Obstructed pilot orifice Pilot gas turned off at automatic pilot Automatic pilot valve is bad Pilot burner will not stay lit Thermocouple is bad Thermocouple is not ...

Page 10: ...KS WITH AIR SPACES BETWEEN THE ROCKS DO NOT OVER LOAD ROCK GRATES Please Use The Following Amount of Lava Rock Per Model GCRB 18 Approximately 3 LBS GCRB 24 Approximately 4 LBS GCRB 36 Approximately 7 LBS GCRB 48 Approximately 9 LBS Notes ...

Page 11: ...X 3 16 1 49 8837112 Label Orifice Size 1 16 218207 28 Tube Pilot 1 50 8837190 Tag Orifice Location 1 17 218207 29 Bracket Pilot GCRB GCB GGM 18 1 51 43813103 Label Warning Hot Surface 1 18 2066154 Pilot Top 1 52 2300100 Bags Poly 36 x 27 x 44 1 19 218207 16 Side Grease Chute 2 53 2065852 Logo Tristar Casted 1 20 22011254 Side Panel LH RH i Line 2 54 2901251 Carton RSC 28 25 X 20 62 X 17 275lbs 1 2...

Page 12: ...12 EXPLODED VIEW TSGCB 18i TSGCRB 18i ...

Page 13: ...4 Side Panel LH RH i Line 2 53 2901255 Post Corner 4 18 30047501 Guide Grease Slide 2 54 2901252 Carton HSC 28 1 4 X 26 5 8 X 17 275 Lbs 1 19 218208 25 Bracket Pilot 1 55 2901229 Pad 21 13 16 X 23 3 16 200 Lbs 1 20 218212 16 Radiant Medium Duty H 4 56 29012 28 Cap FTD 24 25 X 23 25 X 4 275 Lbs 1 21 2092800 Pilot Broiler 1 57 29012 27 Cap FTD 23 43 X 22 06 X 4 275 Lbs 1 22 22011255 Baffle Front Pan...

Page 14: ...14 EXPLODED VIEW TSGCB 24i TSGCRB 24i ...

Page 15: ...PTM 1 52 8837130 Decal Operating Instruction 1 17 218208 25 Bracket Pilot 2 53 2065852 Logo Tristar Casted 1 18 2092800 Pilot Broiler 2 54 8837190 Tag Orifice Location 1 19 8163100 M S Pan Hd Ph 10 32 X 1 4 4 55 43813103 Label Warning Hot Surface 1 20 2092903 Pilot Natural 6 W C 2 56 8837400 Box Label 1 21 2068001 Pilot Valve 2 57 8838700 Manual GCB H GCRB H Champion II 1 22 21820727 Tube Pilot Su...

Page 16: ...16 EXPLODED VIEW TSGCB 36i TSGCRB 36i ...

Page 17: ...1198 Manifold 18 GCBi GCRBi GGMi 4 54 8822325 Decal UL Sanitation NSF Std 4 1 19 22011254 Side Panel LH RH i Line 2 55 29012 27 Cap FTD 23 43 X 22 06 X 4 275 Lbs 2 20 30047501 Guide Grease Slide 4 56 29012 28 Cap FTD 24 25 X 23 25 X 4 275 Lbs 2 21 218212 16 Radiant Med Duty H 8 57 29012 43 Pad 27 X 52 5 200lbs 1 22 218210 51 Body 48 Firebox GGM 1 58 2901229 Pad 21 13 16 X 23 3 16 200lbs 2 23 81973...

Page 18: ...18 EXPLODED VIEW TSGCB 48i TSGCRB 48i ...

Page 19: ...TAR shall bear the normal labor charges for repair of replacement to the extent that such repair or replacement is performed within 35 miles of the office of an authorized service agency within the continental United States and during regular straight time hours Travel outside of the 35 miles and any work performed at overtime or weekend rates would be the responsibility of the owner user Defectiv...

Reviews: