Page 7
IR104-V4 User Guide
Rev A
Specifications
Electrical Specifications
Supply Voltage
+5VDC
Supply Current
Maximum 1A, Typical 110mA (all relays off)
Supply Voltage Tolerance
±5%
Input Voltage
3V to 24V DC or AC
Input Opto-isolation
3000V
Relay Maximum Current
5A @ 30VDC and 250VAC
Relay Maximum Voltage
150VDC, 250VAC
Relay Maximum Power
150W, 1250VA
Operate Time
10ms maximum
Release Time
5ms maximum
Environmental Specifications
Operating Temperature
-25°C to +70°C (-13°F to +158°F)
Mechanical Specifications
Input Relays
20 Opto-isolated Inputs
Output Relays
20 SPST Output Relays
Relay Lifetime
20,000,000 min. / 70,000 min. at rated loads
Dimensions
PC/104 Compliant, 90 × 96mm (3.55 × 3.78")
Component Height
12.49mm (0.492"), slightly over the 0.435" PC/104 standard
Weight
127.12 g (4.48 oz)
MTBF
57,098 hours @ 30°C (86°F) Ambient Temperature
Certifications
1 Introduction
Manufactured in
ISO 9001:2008
,
ISO 14001:2004
&
ANSI/ESD S20.20
Environments
RoHS Compliant
RoHS
compliant
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com