TCB1000 Series User Guide Rev A
3 Configuration
HEART BEAT
These commands allow you to assign a Heart Beat in ms and duty cycle.
TEMP
These commands allow you to configure the on-board low and high temperature limits in Kelvin.
Write Command
Value
Default
Description
HBT=
PERIOD, 1 to 10000ms
2000
Assigns the Heart Beat ms.
HBD=
DUTY CYCLE, 0 to 100%.
50
Assigns the Heart Beat duty cycle in %.
Write Command
Value
Default
Description
TAL=
TEMPERATURE, 233 to 273 K
233
Assigns the low limit temperature in Kelvin.
TAH=
TEMPERATURE 323 to 358 K
358
Assigns the high limit temperature in Kelvin.
Read Command
Description
HBT?
Displays the Heart Beat in ms.
HBD?
Displays the Heart Beat duty cycle in %.
Read Command
Description
TRD?
Returns the current on-board temperature reading in Kelvin.
TAL?
Returns the temperature low limit in Kelvin.
TAH?
Returns the temperature high limit in Kelvin.
Read Command
Description
CAN Bus?
Displays the address and IRQ used by both CAN Bus controllers.
C2?
Displays the address and IRQ used by CAN Bus controller 2.
C2P?
Displays the address used by the CAN Bus controller 2.
C2I?
Displays IRQ used by the CAN Bus controller 2
C2S?
Displays the Slew Rate for CAN Bus controller 2, FAST or SLOW.
Write Command
Value
Default
Description
CP=
ADDRESS
0x600(2)
Assigns the base address for both CAN Bus
controllers.
C1I=
IRQ (5, 6, 7,10, 11, 12, 15)
5
Assigns an IRQ to CAN Bus controller 2.
C1S=
F or S
F
Assigns the Slew Rate for CAN Bus controller 2,
FAST or SLOW.
CAN BUS 2
These commands allow you to configure the IRQ, addresses, and slew rate for the CAN Bus controller 2.
Note
If BASIC CAN Bus: CAN2 address= CAN1 a 0x20, if PeliCAN CAN2 address= CAN1 a 0x80.