SHUT OFF
Lubricate o-ring with Tri-Clover L1011 Sanitary Silicone Spray.
Insert o-ring and split bushing into bonnet.
DIVERT AND ELBOW
Lubricate o-ring with Tri-Clover L1011 Sanitary Silicone Spray.
Insert o-ring into body, place required washer or sleeve on top
of o-ring, place split bushing on top of this component. Fasten
bonnet or body to yoke with three bolts and lock washers.
IMPORTANT:
Replace nylon lock before threading valve stem
onto actuator stem, see section
TYPE 10, 20 & 30 Actuator.
MAINTENANCE
Shut Off
Divert & Elbow
DIVERT AND ELBOW
Apply 60psig air to actuator - (Normally Open Divert and Normally Closed Elbow Valves Only).
SHUT OFF, DIVERT, ELBOW & KETTLE
Push valve stem through bonnet until it meets the actuator stem. Partially thread valve stem onto
actuator stem by hand until nylon lock resistance is felt. Apply an open end wrench over the
valve stem flats, turn clock wise and tighten until valve stem meets actuator stem shoulder.
Place gasket in body groove and clamp together. Cycle valve at least 6 times. Operate all
valves after assembly to be sure they are operating correctly. Inspect all air line connections for
leaks.