WIRING DIAGRAM -  208-230/3/60

STANDARD PSC MOTORS

ELECTRIC DEFROST MODELS - SINGLE EVAPORATOR

COMPR INTERLOCK

   FOR ALL MODELS USING 3 PHASE DEFROST HEATER CONTACTOR

THERMOSTAT

NOTE #4

EVAPORATOR FAN MOTORS AND 

DEFROST HEATERS MUST NOT EXCEED 

1). USE COPPER CONDUCTORS ONLY

3). OVERCURRENT PROTECTION FOR

MAXIMUM VALUE SHOWN ON 

EVAPORATOR NAMEPLATE.

NOTES

2). USE 75°C WIRE (OR HIGHER)

(IF USED)

SWITCH

OR EQUIVALENT

PUMP DOWN

SPACE

(IF USED)

2

1

N

TM

4

X

3

DEFROST CLOCK

PARAGON # 8145

OPTIONAL FACTORY

FACTORY WIRING

WIRING BY OTHERS

ALL FIELD WIRING MUST BE DONE IN 

COMPLIANCE WITH ALL APPLICABLE LOCAL 

AND NATIONAL CODES.

3A-LP ED  3ph.CONTACTOR SINGLE  12/07

 -TERMINAL BLOCK TERMINAL

 -COMPONENT TERMINAL 

CONDUCTORS/WIRING

TERMINALS

NOTE #4

SOL VALVE

N.C.

LIQUID LINE

OR BY OTHERS

AND WIRED ON EVAPORATOR

4.) MAY BE FACTORY INSTALLED-MOUNTED

CIRCUIT

BREAKER

NOTE #3

FUSE OR

CONTACTOR

DEFROST HEATER

T2

T1

C

L2

L1

NOTE #3

BREAKER

FUSE OR

CIRCUIT

GND

L2

L1

L3

T3

L3

 DEFROST HEATERS

H1

H2

H3

DATA PLATE FOR 

MOTOR QUANTITY

1

2

6

3

N

F

4

X

DT

CONTROL

(10.0A MAX.)

FD

& FAN DELAY

DT-DEFROST TERM

DEFROST TERMINATION

FD-FAN DELAY

MTR

FAN

MTR

FAN

GND.

BK

BN

SWITCH

(10.0A MAX.)

MTR

FAN

FAN MOTOR 

REFER TO

EVAPORATOR

POWER PLUGS

HEATER

LIMIT

RD

WH

C

YL

   EVAPORATOR 

REFER TO EVAPORATOR NAMEPLATE 

FOR ELECTRICAL REQUIREMENTS

TPLP

PSC 

60Hz

23/12/16

T30-TPLP-PDI-11

- 12 -

Summary of Contents for TPLP Series

Page 1: ...2 Recommended Expansion Valve Selections 23 Installation Instructions 24 25 Generic Service Parts 26 Warranty 27 Project Information 27 As Built Service Parts Back Questions about this product Email e...

Page 2: ...s approximate 3 4 ID Universal drain fitting for 3 4 MPT or 3 4 flare fitting Factory installed distributor nozzle 460 1 60 PSC motor only EC motors with patented SmartSpeed Technology See page 16 Hea...

Page 3: ...MBLED FEATURES Schrader Valve Located Outside Solenoid Valve Wire pulled through and labeled on each end Solenoid Valve and TXV Mounted Thermostat Mounted on Front of Unit 60Hz TPLP 23 12 16 T30 TPLP...

Page 4: ...7 8 3 5 R407C R404A R507 R22 R134a 0 99 0 92 0 93 1 02 1 03 Low Temperature Models Capacity 6 F P I Low Temp Models 104L 105L 106L 207L 209L 211L 314L 317L 419L 422L 527L 631L Number Of Fans 1 1 1 2 2...

Page 5: ...ACITY A MAX FUSE AMPS HP FLA TOTAL WATTS MIN CIRC AMPACITY A MAX FUSE AMPS 104MAS2 6 1 1 15 0 5 100 0 6 15 1 15 0 6 60 0 8 15 106MAS2 1 1 15 0 5 100 0 6 15 1 15 0 6 60 0 8 15 107MAS2 1 1 15 0 5 100 0...

Page 6: ...200 1 1 15 1 15 1 2 120 1 4 15 1890 8 2 10 3 15 5 3 6 7 15 209LE 2 1 15 1 0 200 1 1 15 1 15 1 2 120 1 4 15 1890 8 2 10 3 15 5 3 6 7 15 211LE 2 1 15 1 0 200 1 1 15 1 15 1 2 120 1 4 15 1890 8 2 10 3 15...

Page 7: ...4 1 5 1 15 209LES4 2 1 15 0 8 200 0 9 15 1890 4 1 5 1 15 211LES4 2 1 15 0 8 200 0 9 15 1890 4 1 5 1 15 314LES4 3 1 15 1 2 300 1 3 15 2730 5 9 7 4 15 317LES4 3 1 15 1 2 300 1 3 15 2730 5 9 7 4 15 419L...

Page 8: ...ORATOR NAMEPLATE FOR ELECTRICAL L1 PARAGON 8145 DEFROST CLOCK OR EQUIVALENT THERMOSTAT CIRCUIT FUSE OR NOTE 3 BREAKER SWITCH PUMP DOWN IF USED NOTE 4 SPACE LIQUID LINE SOLENOID VALVE NOTE 4 N C WITH D...

Page 9: ...VALENT THERMOSTAT CIRCUIT FUSE OR NOTE 3 BREAKER SWITCH PUMP DOWN IF USED NOTE 4 SPACE LIQUID LINE SOLENOID VALVE NOTE 4 N C WITH DEFROST TIME CLOCK 380 400 1 50Hz CONTROL VOLTAGE GND L1 GND IF N 2ND...

Page 10: ...3 DEFROST CLOCK PARAGON 8145 EVAPORATOR OPTIONAL FACTORY FACTORY WIRING WIRING BY OTHERS ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES 2 LP ED 12 07 TERMINAL...

Page 11: ...CE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES 3 LP ED CONTACTOR SINGLE 12 07 TERMINAL BLOCK TERMINAL COMPONENT TERMINAL CONDUCTORS WIRING TERMINALS NOTE 4 SOL VALVE N C LIQUID LINE OR BY OTHERS AND...

Page 12: ...WITH ALL APPLICABLE LOCAL AND NATIONAL CODES 3A LP ED 3ph CONTACTOR SINGLE 12 07 TERMINAL BLOCK TERMINAL COMPONENT TERMINAL CONDUCTORS WIRING TERMINALS NOTE 4 SOL VALVE N C LIQUID LINE OR BY OTHERS AN...

Page 13: ...K PARAGON 8145 EVAPORATOR OPTIONAL FACTORY FACTORY WIRING WIRING BY OTHERS ALL FIELD WIRING MUST BE DONE IN COMPLIANCE WITH ALL APPLICABLE LOCAL AND NATIONAL CODES 7 LP ED CONTACTOR SINGLE 12 07 TERMI...

Page 14: ...P ED CONTACTOR MULTI 12 07 TERMINAL BLOCK TERMINAL COMPONENT TERMINAL CONDUCTORS WIRING TERMINALS DATA PLATE FOR MOTOR QUANTITY EVAPORATOR REFER TO POWER PLUGS FAN MOTOR H2 NOTE 4 SOL VALVE L2 L1 N C...

Page 15: ...MINAL CONDUCTORS WIRING TERMINALS DATA PLATE FOR MOTOR QUANTITY EVAPORATOR REFER TO POWER PLUGS FAN MOTOR NOTE 4 SOL VALVE L2 L1 N C LIQUID LINE L2 T2 L1 C T1 GND OR BY OTHERS AND WIRED ON EVAPORATOR...

Page 16: ...talled thermostat a field wired SPDT type thermostat is required 0 2000 4000 6000 8000 10000 12000 14000 16000 18000 20000 0 50 100 150 200 250 300 350 400 450 500 Energy Consumption Watt Hours Time m...

Page 17: ...WIRING DIAGRAM 115 1 60 208 230 1 60 OPTIONAL EC MOTORS with AIR DEFROST MODELS TPLP ECM 60Hz 23 12 16 T30 TPLP PDI 11 17...

Page 18: ...WIRING DIAGRAM 208 230 1 60 OPTIONAL EC MOTORS with ELECTRIC DEFROST MODELS TPLP ECM 60Hz 23 12 16 T30 TPLP PDI 11 18...

Page 19: ...WIRING DIAGRAM 208 230 1 60 OPTIONAL EC MOTORS with ELECTRIC DEFROST MODELS MULTIPLE EVAPORATORS TPLP ECM 60Hz 23 12 16 T30 TPLP PDI 11 19...

Page 20: ...4 639MA 192 87 Electric Defrost Models MODEL NUMBER SHIPPING WEIGHT LB kg 104ME 104LE 103VE 49 22 106ME 105LE 104VE 51 23 107ME 106LE 105VE 53 24 209ME 207LE 206VE 76 34 211ME 209LE 208VE 80 36 214ME...

Page 21: ...1 N A N A 1 1 8 3 8 3 8 419L 4 78 1 4 1988 32 5 8 829 32 5 8 829 1 1 8 3 8 3 8 422L 4 78 1 4 1988 32 5 8 829 32 5 8 829 1 1 8 3 8 3 8 527L 5 94 1 4 2394 32 5 8 829 48 5 8 1235 1 3 8 3 8 1 2 631L 6 110...

Page 22: ...407C R22 R134a 104M N A EBQE AA C EBQE AAA VC EBQE AAA JC 106M L 1 2 EBQE AA C EBQE AA VC EBQE AA JC 107M L 1 2 EBQE A C EBQE AA VC EBQE AA JC 209M L 3 4 EBQE A C EBQE AA VC EBQE AA JC 211M L 1 EBQE A...

Page 23: ...6V L 2 1 2 EBQE A VC EBQE B VZP40 EBQE B VZP40 EBQE B VZP40 EBQE B VZP40 419V G 3 EBQE A VC EBQE B VZP40 EBQE B VZP40 EBQE B VZP40 EBQE B VZP40 523V G 4 EBQE B VC EBQE B VZP40 EBQE C VZP40 EBQE C VZP4...

Page 24: ...ion should be given to the coil location in order to minimize the piping run length to the condensing unit and floor drain EXPANSION VALVE TXV PRE SELECTED Locate the expansion valve bulb on a horizon...

Page 25: ...YCLE PIPING Refrigeration grade piping must be used for all field refrigeration piping Refrigerant line sizes are important and may not be the same size as the coil connections Consult ASHRAE handbook...

Page 26: ...SERVICE PARTS TPLP 60Hz FOR SERVICE PARTS LOOK UP visit http www t rp com serv_parts htm email parts t rp com call 1 844 893 3222 x501 23 12 16 T30 TPLP PDI 11 26...

Page 27: ...duct in a corrosive atmosphere c damages caused by any unauthorized alteration or repair of the system affecting the product s reliability or performance d damages caused by improper matching or appli...

Page 28: ...ION AIR CONDITIONING CANADA CORP 159 Roy Blvd Brantford Ontario Canada N3R 7K1 PHONE 519 751 0444 800 463 9517 FAX 519 753 1140 www t rp com Due to National Refrigeration s policy of continuous produc...

Reviews: