background image

TB/TI Thermistor Insertion Temperature Sensor Installation Instructions TG200727 Issue 5, 07-Mar-2016.

TB/TI 

Installation Instructions

Please  send  any  comments  about  this  or  any  other  Trend  technical 

publication to [email protected]

© 2016

 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the Environmental and Combustion Controls 

Division of Honeywell Technologies Sàrl, Z.A. La Pièce, 16, 1180 Rolle, Switzerland by its Authorized Representative, Trend Control Systems Limited.

Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation 

to notify any person of such revisions or changes.

Trend Control Systems limited

Albery House, Springfield Road, Horsham, West Sussex, RH12 2PQ, UK. Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trendcontrols.com

 

TR CU 

Certification

4 DISPoSal

Weee Directive:

At  the  end  of  their  useful  life  the  packaging  and 

product  should  be  disposed  of  by  a  suitable 

recycling centre.

Do not dispose of with normal household waste.

Do not burn.

Summary of Contents for Thermistor TBTI

Page 1: ...ature Sensor Installation Instructions TG200727 6 mm 0 24 400 mm 15 75 94 mm 3 70 57 mm 2 24 113 mm 4 45 50 mm 1 97 6 mm compression fitting 3 x 4 mm diam holes on a 30 mm 1 18 PCD Pitch Circle Diamet...

Page 2: ...therwise use averaging sensor 40 C 40 F 50 C 122 F to 40 C 40 F 110 C 230 F to Duct Duct H O 2 0 RH 95 RH Protection IP67 NEMA6 Ensure no stratification e g downstream of mixing valves junctions d 40...

Page 3: ...et length clip engages in groove probe is forced against end of pocket tighten screw over bush InSTall SenSoR InTo PoCKeT If using Universal Fitting Kit if pocket has clip retaining groove push clip o...

Page 4: ...ST DEPTH OF PROBE drill 3 holes screw on flange mounted flange 7 mm 0 28 42 5 mm 1 67 85 mm 3 35 2 off 2 off No 6 3 4 s s self tapping screws integral foam gasket compression fitting duct mounting fla...

Page 5: ...20x1 5 cable gland supplied Or use M20 flexible conduit not supplied Recommended cable TP 1 1 22 HP 200 600V Belden 8761 Terminal size 0 5 to 2 5 mm2 20 to 14 AWG Sensor IQ controller COM 0V IN polari...

Page 6: ...he following SET Unique Sensor References should be used Thermistor Thermistor TBTI 30 C to 110 C Thermistor TBTI F 22 F to 230 F Alternatively set scaling mode to 5 characterise and enter scaling man...

Page 7: ...7 Issue 5 07 Mar 2016 7 Installation Instructions TB TI There are no serviceable parts inside the unit Cleaning of the unit should be carried out in order to avoid buildup of dust or other containment...

Page 8: ...e Switzerland by its Authorized Representative Trend Control Systems Limited Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the conte...