TB/TS/KO, /OS, /KOS, /KOF, /KOSF Installation Instructions TG200606 Issue 3, 26-Aug-2014

TB/TS/KO, /OS, /KOS, /KOF, /KOSF 

Installation Instructions

Please send any comments about this or any other Trend technical publication to [email protected]

© 2014

 Honeywell Technologies Sàrl, ECC Division. All rights reserved. Manufactured for and on behalf of the Environmental and Combustion Controls 

Division of Honeywell Technologies Sàrl, Z.A. La Pièce, 16, 1180 Rolle, Switzerland by its Authorized Representative, Trend Control Systems Limited.

Trend Control Systems Limited reserves the right to revise this publication from time to time and make changes to the content hereof without obligation 

to notify any person of such revisions or changes.

Trend Control Systems limited

Albery House, Springfield Road, Horsham, West Sussex, RH12 2PQ, UK. Tel:+44 (0)1403 211888 Fax:+44 (0)1403 241608 www.trendcontrols.com

Trend Control Systems USa

6670  185th  Avenue  NE,  Redmond,  Washington  98052,  USA.  Tel:(425)  897-3900  Fax:(425)  869-8445  www.trend-americas.com

11

Test system

10

Set up IQ Sensor Types

4 DISPOSal

Weee Directive:

At  the  end  of  their  useful  life  the  packaging  and 

product  should  be  disposed  of  by  a  suitable 

recycling centre.

Do not dispose of with normal household waste.

Do not burn.

For  IQ2  version  2.1  or  greater,  IQ3,  IQ4,  and  IQeco,  the 

recommended method of setting the sensor scaling is to use 

the ‘Unique Sensor Reference’ provided in SET, see below 

for details.

For  IQ1,  IQ2  Version  2.0  or  lower,  see  Sensor  Scaling 

Reference Card TB100521A, and set up manually in SET.

The input channel must be set to the appropriate input type (see controller documentation for details) and the sensor 

type module must be set up with the correct scaling. If the SET pre-defined strategy is used the sensor scaling will 

have been set up.  

-

+

/K

/O

/F

/OS

 T 

 SP 

∆ 

yellow

green

3 InSTallaTIOn 

(continued)

Knob: 

The input channel used should be set for thermistor 

(T), and sensor scaling set as below.

Controller

Unique Sensor Reference

notes

IQ1, IQ2 v2.0 

or lower

Set up manually in SET

IQ2  v2.1  or 

greater, IQ3, 

and IQ4

Knob TB 3 deg trim

Guaranteed ±3 

trim

Knob T 3 deg trim

±3 ±20% linear 

trim

IQeco

(Knob TB 05 deg trim)

Type 102 - Potentiometer

-0.5  to  +  0.5 

deg trim

Thermistor: 

The  input  channel  used  should  be  set  for 

thermistor (T), and sensor scaling set as below.

Controller

Unique Sensor Reference

notes

IQ1, IQ2 v2.0 

or lower

Set up manually in SET

IQ2  v2.1  or 

greater, IQ3, 

and IQ4

Thermistor TBTS

Value in °C

Thermistor TBTS F

Value in °F

IQeco

(10k Therm DegC TBTS)

Type 101 - Thermistor °C

Value in °C

(10k Therm DegC TBTS)

Type 108 - Thermistor °F

Value in °F

Fan Control: 

The input channel should be set for voltage (V), 

and sensor scaling set as below.

Controller

Unique Sensor Reference

notes

IQ2  v2.0  of 

lower

Set up manually in SET

IQ2  v2.1  or 

greater, IQ3, 

and IQ4

Fan Control V

produces 

range 0 to 9.7

Fan KO enum

produces fan 

speed settings 

for /O sensors  

- see TB/TS 

data sheet

IQeco

(Fan TBTS KOF)

Type  111  -  TBTS  Fan  Speed 

Control

For TBTS 

KOF, KOSF