VIBRATION
* (k) Equals the factor of uncertainty, which allows for variations in
measurement and production.
Vibration Data figures are tri-axial, which gives the total vibration
emission.
Because of various factors, the range of vibration from these tools
may vary between 2.337m/s
2
& 3.3m/s
2
. The vibration is dependent
on the task, the operators grip and feed force employed etc.
NOTE: The above vibration levels were obtained from tri-axial
measurements to comply with the requirements of “The Control of
Vibration at Work Regulations 2005*” and the revisions to the (8662)
now EN ISO 28927 and EN ISO 20643 series of standards.
These values are at least 1.4 times larger than the values obtained
from single axis measurements.
Based on European Union Council Directive 2002/44/EC (Physical
Agents (Vibration) Directive)
This tool has been designed and produced in accordance with the
following directives:
2006/42/EC Machinery Directive
TECHNICAL SPECIFICATIONS
Trelawny SPT Ltd
Trelawny House, 13 Highdown Road, Sydenham Industrial Estate, Leamington Spa, Warwickshire,
CV31 1XT, United Kingdom
Telephone: +44 (0)1926 883781
Fax: +44 (0)1926 450352
Email: [email protected]
Website: www.trelawnyspt.com
© TSPT UK 2012 Part No: 735.5320 issue 1
SURFACE PREPARATION TECHNOLOGY
All rights reserved. Any unauthorised use or copying of the contents or part thereof is prohibited.
This applies to trademarks, model denominations, part numbers and drawings.
Use only genuine Trelawny spares.
The use of non-Trelawny spare parts invalidates the warranty.
FAULT
CAUSE
ACTION
Blown electrical supply fuse.
Replace fuse.
Electric motor stops
suddenly
Motor overload protection activated, caused by to
heavier cut being made.
Disconnect electricity supply at mains and reset button inside
starter box, reduce depth of cut.
RCD protection tripped
Investigate cause, rectify and reset RCD protection.
Planer is slow or
erratic
Drive Belts slack or failed.
Replace Belts or adjust tension.
Worn Drum Cutters
Replace Cutters.
Failed cutter shaft
Inspect drum inserts, replace inserts and cutter shaft as required.
No drive to rear
wheels
Incorrect electrical phase
See page 6 for rectification method.
Insufficient hydraulic fluid in tank.
Rectify hydraulic leak and refill with correct hydraulic oil.
Hydraulic drive belt slack or failed
Tighten or replace drive belt
If problem has not been cured by above actions, contact your local Trelawny agent or engine manufacturer for advice or rectification.
Trouble Shooting
If your company has any problem with our products or would like to
discuss the possibility of an improvement being made to them, then
please do not hesitate to contact us.
Your comments are both important and appreciated.
Technical Specifications
POWER OUTPUT (HP)
15
VOLTAGE
380/415
CYCLES
50
CUTTERHEAD SPEED (RPM)
650
STARTER
STAR / DELTA
TRAVEL SPEED mtr/min
0 -12
LENGTH
1230
PLUG SIZE
32amp / 5pin
MAXIMUM CABLE LENGTH (6mm)
75 Meters
GENERATOR
25kVA
HYDRAULIC OIL
HM46
HYDRAULIC OIL TANK CAPACITY
6 Litres
WIDTH
590
WEIGHT (Kg) with drum
339
CUTTING WIDTH (mm)
320
WORKING DISTANCE FROM WALL (mm)
40
NOISE L
wa
97.2
L/
Aeq t
79.2
VIBRATION (Handle) Aeq m/s
2
(K)*
2.337