background image

5

EN

M

use GP

 

minipool

2

ChECkIng MInIPool InTEgrITy

After having removed the minipool from the packing, check its integrity.

Check:

•  That there is no visible structural damage;

•  That there are no cracks in the surface of the minipool or in the outer covering (cracks due to incorrect transport 

or support are not covered by the warranty);

•  The correct position of the sleeves and pipes;

•  That any ties are not loosened.

If you notice any anomalies, do not proceed with the installation but rather promptly contact the Manufacturer.

Preliminary operations

1

PrEPArATIonS AnD ChoICE 

oF PoSITIon

The pre-installation sheet supplied at the time 

of purchase provides all the information neces-

sary for a correct preparation of the installation 

environments.

Before installing the minipool, check that everything 

has been prepared.

 Find below a quick checklist, for 

complete information always refer to the pre-installation 

sheet.

Check that:

•  A platform or a recess (in the case of recessed installa-

tions) of reinforced concrete, with a minimum thickness 

of 10 cm, has been created, perfectly flat and suitable 

for supporting the weight of the minipool and the 

people within.

•  Ø15 cm vents have been installed to ensure proper 

ventilation of the technical compartment.

•  Drainage grating around the perimeter has been 

installed to help preserve the equipment and the 

structure (even for indoor installations);

•  Non-slip flooring has been installed in the area around 

the minipool;

•  For a recessed installation, 

a technical inspection port 

measuring at least 50 cm wide has been prepared on 
all sides of the minipool

;

•  The connections to the electrical grid have been made 

in compliance with current regulations in force in the 

country of installation;

•  A water softener has been installed for the water used 

to fill the minipool if the water has a high degree of 

hardness;

•  For outdoor recessed versions, the walls have been 

insulated to protect against the cold.

More information

ouTDoor InSTAllATIon

Preparations

To run the electric cables from the main electrical panel 

to the minipool underground ducts must be used and 

adequately protected against freezing by using insula-

tion. It is also recommended to add drainage points in 

them to prevent standing water.

Choice of position

: take into account the proximity of 

trees or hedges, and note that debris (e.g., leaves) can 

cause damage to the equipment over time that is not 

covered by warranty and make maintenance more ex-

pensive and frequent. It is also recommended to always 

install flooring around the minipool, possibly anti-slip.

InDoor InSTAllATIon

Preparations

: in the area used to access the minipool 

it is recommended to install anti-slip flooring.

The evaporation of water in the minipool in the pres-

ence of high internal temperatures can generate very 

high levels of humidity in the environment.

To avoid this problem, provide good natural or forced 

ventilation in the installation environment and, if nec-

essary, a dehumidification system. Damage caused by 

this phenomenon is not covered by the manufacturer 

warranty.

Choice of position

: Always take into account the size 

of the minipool: narrow passages, doors and steps can 

be an obstacle to its transport to the desired place.

Summary of Contents for Muse GP

Page 1: ...Installation manual Muse GP minipool...

Page 2: ...ead this manual carefully before installing it The Treesse team is always available for any information or request for assistance that may be required during installation GRUPPO TRE S s p a Telephone...

Page 3: ...___ 8 3 CONNECTIONS REQUIRED__________________________________________________________ 9 4 WATER SUPPLY_____________________________________________________________________ 12 CHARACTERISTICS OF THE W...

Page 4: ...at do not follow the information provided in this manual can cause damages injuries or fatal accidents and null and void the warranty During the installation of the minipool do not place objects insid...

Page 5: ...on port measuring at least 50 cm wide has been prepared on all sides of the minipool The connections to the electrical grid have been made in compliance with current regulations in force in the countr...

Page 6: ...ys to reach the desired place of installation Movement must be carried out using personal protective equipment e g gloves safety shoes etc and taking all the necessary safety precau tions for those in...

Page 7: ...into the prepared space If it was not possible to provide a technical inspec tion port on all sides of the minipool a pneu matic lift is available optional to be request ed from the Manufacturer in o...

Page 8: ...r Before installation it is recommended to carefully read the safety warnings at the beginning of this manual and to always operate in perfect physical and mental condition The installer qualified and...

Page 9: ...mbing connection to an exchanger optional if provided see following page The following pages will provide detailed explanations of how to perform these preparations Examples of outdoor indoor minipool...

Page 10: ...1 BL2 HTR Cromo 230V EVc EVs EVclv J49 J48 230V heater exchanger control cable C switch recommended OUT outgoing cold water P circulator not supplied PR recirculation pump S exchanger not supplied The...

Page 11: ...nical inspection port IN water inlet OUT water outlet 230V IN PR F C CP 230V circulator control cable OUT water outlet IN water inlet PR recirculation pump F filter C control unit Inlet connection 1 1...

Page 12: ...ariations Water pH What is pH The pH is a chemical parameter that gives an idea of the acidity or basicity of the water It can assume values between 0 and 14 By definition water is considered neutral...

Page 13: ...he instructions provided by the manufacturer of the cleaning product used Paper filters should be mounted when they are com pletely dry 5 2 1 4 3 6 emptying the minipool CLICK 1 2 4 3 Emptying takes p...

Page 14: ...ty equal to 60A or in any case adequate for the absorption of the bathtub Controlled by a differential switch no larger than 30mA The control unit s power supply cable must be of the H05 type with thr...

Page 15: ...e minipool for a distance of at least 60 cm and a height of 230 cm Make sure that The minipool is level and stable Electrical connections are made correctly in accordance with local and national codes...

Page 16: ...the quality of the water supply This is very important for the well being of the users and for the long life of the minipool For more information see chapter Characteristics of the water supply on pag...

Page 17: ...ntrol panel display lights up press the Jet key once to activate pump 1 at low speed and press it a second time to increase the speed If you have a second pump press the Jet2 key to activate it The pu...

Page 18: ...ndicates that it is necessary to wait before knowing the water temperature in order for it to be detected correctly in fact the pump dedicated to water circulation must have been in operation for at l...

Page 19: ...ption No water in the heater All minipool functions are disabled After solving the problem remove and restore the power to initialize the water heating procedure See the Water flow problems section Th...

Page 20: ...description The sensor connected to the temperature survey or the circuit sensor do not work Solutions Contact Technical Service VARIOUS TYPES OF MESSAGES DISPLAY SCREEN DESCRIPTION OF SIGNALS AND PO...

Page 21: ...Solutions Contact Technical Service Configuration error The minipool doesn t start Solutions Contact Technical Service GFCI fault The system is not connected to the GFCI M036 Problem description ONLY...

Page 22: ...22 EN Muse GP minipool Mount the wood or laminate resin panels as shown in the figures below Decorative panels 2 3 1 1 3 2...

Page 23: ...is especially useful if the minipool is installed outdoors In this case it might be useful to anchor it with lashing straps in order to prevent the wind from moving it or blowing it off Covering Maxim...

Page 24: ...www gruppotreesse it GRUPPO TRE S s p a 01036 Nepi VT Italy S S Cassia km 36 400 Settevene industrial area tel 39 0761 527242 fax 39 0761 527223 info gruppotres it Muse GP installation Edition 10 2020...

Reviews: